8D–512

WIRING SYSTEM

IS THE CIRCUIT BREAKER C/B-2 (30A) NORMAL?

YES

IS THE GROUND GROUNDED SECURELY?

REPLACE THE CIRCUIT BREAKER

NO

YES

REPAIR A POOR CONNECTION AT THE CONNECTORS
OR AN OPEN CIRCUIT BETWEEN 4   H-57   AND THE
GROUND

REPAIR A POOR CONNECTION AT THE
CONNECTORS OR AN OPEN CIRCUIT
BETWEEN CIRCUIT BREAKER AND 1   T-2

NO

YES

IS THE BATTERY VOLTAGE APPLIED BETWEEN 1   T-2
AND GROUND?

GROUND IT SECURELY

NO

Driver Seat

1.

Power Seat Does Not Operate At Any Direction

WIRING SYSTEM

8D–513

IS TILT & SLIDE SWITCH NORMAL?

YES

IS FRONT TILT MOTOR NORMAL?

REPAIR OR REPLACE THE TILT &
SLIDE SWITCH

NO

YES

REPAIR A POOR CONNECTION AT THE CONNECTORS OR AN

OPEN CIRCUIT BETWEEN 1   T-1   AND 1   T-4   , 6   T-1   AND

2   T-4   , 3   T-1   AND 1   T-3   , 8   T-1   AND 2   T-3   OR 3   T-3

REPAIR OR REPLACE THE FRONT TILT
MOTOR

NO

IS TILT & SLIDE SWITCH NORMAL?

YES

IS REAR TILT MOTOR NORMAL?

REPAIR OR REPLACE THE TILT &
SLIDE SWITCH

NO

YES

REPAIR A POOR CONNECTION AT THE CONNECTORS OR AN

OPEN CIRCUIT BETWEEN 2   T-1   AND 1   T-6   , 7   T-1   AND

2   T-6   , 4   T-1   AND 1   T-5   , 9   T-1   AND 2   T-5   OR 3   T-5

REPAIR OR REPLACE THE REAR TILT
MOTOR

NO

2.

Front Tilt Mechanism Does Not Operate

3.

Rear Tilt Mechanism Does Not Operate

8D–514

WIRING SYSTEM

IS TILT & SLIDE SWITCH NORMAL?

YES

IS SLIDE MOTOR NORMAL?

REPAIR OR REPLACE THE TILT &
SLIDE SWITCH

NO

YES

REPAIR A POOR CONNECTION AT THE CONNECTORS OR AN
OPEN CIRCUIT BETWEEN 5   T-1   AND 1   T-7   , 10   T-1   AND
2   T-7   OR 2   T-2

REPAIR OR REPLACE THE SLIDE
MOTOR

NO

IS RECLINER SWITCH NORMAL?

YES

IS RECLINER MOTOR NORMAL?

REPAIR OR REPLACE THE RECLINER
SWITCH

NO

YES

REPAIR A POOR CONNECTION AT THE CONNECTORS  3   T-11   ,
6   T-11   , 2   T-11   , 5   T-11   AND 4   T-11

REPAIR OR REPLACE THE RECLINER
MOTOR

NO

4.

Sliding Mechanism Does Not Operate

5.

Reclining Mechanism Does Not Operate

WIRING SYSTEM

8D–515

IS THE CIRCUIT BREAKER C/B-2 (30A) NORMAL?

YES

IS THE GROUND SECURELY GROUNDED?

REPLACE THE CIRCUIT BREAKER

NO

YES

GROUND IT SECURELY

NO

YES

REPAIR A POOR CONNECTION AT THE CONNECTORS  OR AN
OPEN CIRCUIT 2   T-9   AND THE GROUND

REPAIR A POOR CONNECTION AT THE
CONNECTORS OR AN OPEN CIRCUIT
BETWEEN CIRCUIT BREAKER AND 1   T-9

NO

IS THE BATTERY VOLTAGE APPLIED BETWEEN 1   T-9
AND GROUND?

Passenger Seat

1.

Power Seat Does Not Operate At Any Direction

 

 

 

 

 

 

 

Content   ..  2826  2827  2828  2829   ..