|
|
BRC-266 < COMPONENT DIAGNOSIS > [TYPE 3] VDC OFF INDICATOR LAMP VDC OFF INDICATOR LAMP Description INFOID:0000000005275357 × : ON –: OFF Component Function Check INFOID:0000000005275358 1. VDC OFF INDICATOR LAMP OPERATION CHECK 1 Check that the lamp illuminates for approximately 2 seconds after the ignition switch is turned ON. YES >> GO TO 2 NO >> Go to diagnosis procedure. Refer to BRC-266, "Diagnosis Procedure" 2. VDC OFF INDICATOR LAMP OPERATION CHECK 2 Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the YES >> Inspection End NO >> Check VDC OFF switch. Refer to BRC-262, "Diagnosis Procedure" . Diagnosis Procedure INFOID:0000000005275359 1. CHECK VDC OFF SWITCH Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the YES >> GO TO 2 NO >> Check VDC OFF switch. Refer to BRC-262, "Diagnosis Procedure" . 2. CHECK SELF-DIAGNOSIS Perform ABS actuator and electric unit (control unit) self-diagnosis. Refer to BRC-212, "CONSULT-III Function Is the inspection result normal? YES >> GO TO 3 NO >> Check items displayed by self-diagnosis. 3. CHECK COMBINATION METER Check if the indication and operation of combination meter are normal. Refer to . Is the inspection result normal? YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC-300, "Removal and Installa- . NO >> Replace combination meter. Refer to MWI-95, "Removal and Installation" Condition VDC OFF indicator lamp Ignition switch OFF – For 2 seconds after turning ON ignition switch × 2 seconds later after turning ON ignition switch – VDC OFF switch turned ON. (VDC function is OFF.) × VDC/TCS function is malfunctioning. × ABS function is malfunctioning. × EBD function is malfunctioning. × |