Content .. 1013 1014 1015 1016 ..
IPDM E/R (INTELLIGENT POWER DISTRIBUTION MODULE ENGINE ROOM) WW-39 < ECU DIAGNOSIS INFORMATION > C D E F G H I J K M A B WW N O P 35 L/B Wiper high speed Output ON or START Wiper switch OFF, LO, INT Battery voltage HI 0V 37 Y Power generation Output — Ignition switch ON 6.3 V 40% is set on "Active test," "ALTER- 3.8 V 40% is set on "Active test," "ALTER- 1.4 V 38 B Ground Input — — 0V 39 L CAN-H — ON — — 40 P CAN-L — ON — — 42 GR Oil pressure switch Input — Engine running Battery voltage Engine stopped 0V 43 L/Y Wiper auto stop sig- Input ON or START Wiper switch OFF, LO, INT Battery voltage 44 BR Daytime light relay Input ON Daytime light system active 0V Daytime light system inactive Battery voltage 45 G/W Horn relay control Input ON When door locks are operated using → ON)* Battery voltage → 0V 46 GR Fuel pump relay con- Input — Ignition switch ON or START 0V Ignition switch OFF or ACC Battery voltage 47 O Throttle control mo- Input — Ignition switch ON or START 0V Ignition switch OFF or ACC Battery voltage 48 B/R Starter relay (inhibit Input ON or START Selector lever in "P" or "N" 0V Selector lever any other position Battery voltage Terminal Wire color Signal name Signal input/ output Measuring condition Reference value (Approx.) Igni- tion switch Operation or condition JPMIA0001GB JPMIA0002GB JPMIA0003GB |