EXL-180 < DTC/CIRCUIT DIAGNOSIS > [HALOGEN TYPE] DAYTIME RUNNING LIGHT RELAY CIRCUIT DAYTIME RUNNING LIGHT RELAY CIRCUIT Component Function Check INFOID:0000000009653155 1. CHECK DAYTIME RUNNING LIGHT OPERATION CONSULT ACTIVE TEST 1. Select “DAYTIME RUNNING LIGHT” of BCM (HEADLAMP) active test item. 2. With operating the test items, check that daytime running light operation. Is the inspection result normal? YES >> Daytime running light relay circuit is normal. NO >> Refer to EXL-180, "Diagnosis Procedure" . Diagnosis Procedure INFOID:0000000009653156 1. CHECK DAYTIME RUNNING LIGHT RELAY FUSE 1. Turn ignition switch OFF. 2. Check that the following fuse is not fusing. Is the inspection result normal? YES >> GO TO 2. NO >> Replace the fuse after repairing the applicable circuit. 2. CHECK DAYTIME RUNNING LIGHT RELAY POWER SUPPLY 1. Remove daytime running light relay. 2. Check voltage between daytime running light relay harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness. 3. CHECK DAYTIME RUNNING LIGHT RELAY Check daytime running light relay. Refer to EXL-181, "Component Inspection" . Is the inspection result normal? YES >> GO TO 4. NO >> Replace daytime running light relay. 4. CHECK DAYTIME RUNNING LIGHT RELAY CONTROL SIGNAL OUTPUT CONSULT ACTIVE TEST 1. Install daytime running light relay. 2. Turn ignition switch ON. 3. Select “DAYTIME RUNNING LIGHT” of BCM (HEADLAMP) active test item. 4. With operating the test item, check voltage between IPDM E/R harness connector and ground. On : Daytime running light ON Off : Daytime running light OFF Unit Fuse No. Capacity Daytime running light relay #59 10 A (+) ( − ) Voltage (Approx.) Daytime running light relay Connector Terminal E17 1 Ground Battery voltage 5 |