SECURITY INDICATOR LAMP SEC-207 < DTC/CIRCUIT DIAGNOSIS > [WITHOUT INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B SEC N O P 3. Check continuity between combination meter harness connector and ground. Is the inspection result normal? YES >> Replace combination meter. Refer to MWI-93, "Removal and Installation" NO >> Repair or replace harness. Combination meter BCM Continuity Connector Terminal Connector Terminal M34 18 M65 23 Existed Combination meter Ground Continuity Connector Terminal M34 18 Not existed |