INL-40

< DTC/CIRCUIT DIAGNOSIS >

POWER SUPPLY AND GROUND CIRCUIT

1.

CHECK FUSES AND FUSIBLE LINK

Check that the following fuses and fusible link are not blown.

Is the fuse blown?

YES

>> Replace the blown fuse or fusible link after repairing the affected circuit.

NO

>> GO TO 2.

2.

CHECK POWER SUPPLY CIRCUIT

1. Turn ignition switch OFF.

2. Disconnect BCM connectors.

3. Check voltage between BCM connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair harness or connector.

3.

CHECK GROUND CIRCUIT

Check continuity between BCM connector and ground.

Is the inspection result normal?

YES

>> Inspection End.

NO

>> Repair harness or connector.

Terminal No.

Signal name

Fuses and fusible link No.

37

Battery power supply

8 (10A)

42

12 (10A)

50

G (40A)

11

Ignition switch ACC or ON

18 (10A)

38

Ignition switch ON or START

2 (10A)

BCM

Ground

Ignition switch position

Connector

Terminal

OFF

ACC

ON

M18

11

0 V

Battery voltage

Battery voltage

37

Battery voltage

38

0 V

0 V

M19

42

Battery voltage

Battery voltage

50

BCM

Ground

Continuity

Connector

Terminal

M19

55

Yes

BATTERY SAVER OUTPUT/POWER SUPPLY CIRCUIT

INL-41

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

K

M

A

B

INL

N

O

P

BATTERY SAVER OUTPUT/POWER SUPPLY CIRCUIT

Description

INFOID:0000000009695418

Provides the battery saver output/power supply. Also cuts the power supply when the interior lamp battery

saver is activated.

Component Function Check

INFOID:0000000009695419

1.

CHECK BATTERY SAVER OUTPUT/POWER SUPPLY FUNCTION

CONSULT

1. Turn ignition switch ON.

2. Turn each interior lamp to the ON position.

-

Interior room lamp

-

Map lamp (if equipped)

-

Cargo lamp

3. Select BATTERY SAVER of BCM (BATTERY SAVER) active test item.

4. While operating the test item, check that each interior room lamp turns ON/OFF.

Is the inspection result normal?

YES

>> Battery saver output/power supply circuit is normal.

NO

>> Refer to 

INL-41, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009695420

Regarding Wiring Diagram information, refer to 

INL-21, "Wiring Diagram"

.

1.

CHECK BATTERY SAVER OUTPUT/POWER SUPPLY OUTPUT

CONSULT

1. Turn ignition switch ON.

2. Select BATTERY SAVER of BCM (BATTERY SAVER) active test item.

3. While operating the test item, check voltage between BCM connector and ground.

With Intelligent Key

Without Intelligent Key

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Replace BCM after making sure battery saver output/power supply circuit is not shorted to volt-

age. Refer to 

BCS-70, "Removal and Installation"

 (with Intelligent Key) or 

BCS-127, "Removal

and Installation"

 (without Intelligent Key).

2.

CHECK BATTERY SAVER OUTPUT/POWER SUPPLY OPEN CIRCUIT

1. Turn ignition switch OFF.

OFF

: Interior room lamp OFF

ON

: Interior room lamp ON

(+)

(-)

Test item

Voltage

Connector

Terminal

BATTERY SAVER

M99

56

Ground

OFF

0V

ON

Battery voltage

(+)

(-)

Test item

Voltage

Connector

Terminal

BATTERY SAVER

M19

43

Ground

OFF

0V

ON

Battery voltage

INL-42

< DTC/CIRCUIT DIAGNOSIS >

BATTERY SAVER OUTPUT/POWER SUPPLY CIRCUIT

2. Disconnect the following connectors.

-

BCM 

-

Interior room lamp

-

Map lamp (if equipped)

-

Cargo lamp 

3. Check continuity between BCM connector and each interior lamp connector.

With Intelligent Key

Without Intelligent Key

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace the harness or connector.

3.

CHECK BATTERY SAVER OUTPUT/POWER SUPPLY SHORT CIRCUIT

Check continuity between BCM connector and ground.

With Intelligent Key

Without Intelligent Key

Is the inspection result normal?

YES

>> Check that each interior room lamp has no internal short circuit.

NO

>> Repair or replace the harness or connector.

BCM

Each interior lamp

Continuity

Connector

Terminal

Connector

Terminal

M99

56

Interior room lamp

R7

2

Yes

Map lamp (if equipped)

R2

4

Trunk room lamp 

B21

1

BCM

Each interior lamp

Continuity

Connector

Terminal

Connector

Terminal

M19

43

Interior room lamp

R7

2

Yes

Map lamp (if equipped)

R2

4

Trunk room lamp 

B21

1

Connector

Terminal

Continuity

M99

56

Ground

No

Connector

Terminal

Continuity

M19

43

Ground

No

INTERIOR ROOM LAMP CONTROL CIRCUIT

INL-43

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

K

M

A

B

INL

N

O

P

INTERIOR ROOM LAMP CONTROL CIRCUIT

Description

INFOID:0000000009695421

Controls each interior room lamp (ground side) by PWM signal.

NOTE:

PWM signal control period is approximately 250 Hz (in the gradual brightening/dimming).

Component Function Check

INFOID:0000000009695422

CAUTION:

 Before performing the diagnosis, check that the following are normal.

• Interior room lamp power supply

• Map lamp bulb

• Room lamp bulb

1.

CHECK INTERIOR ROOM LAMP CONTROL FUNCTION

CONSULT

1. Switch the map lamp switch or interior room lamp switch to DOOR.

2. Turn ignition switch ON.

3. Select INT LAMP of BCM (INT LAMP) ACTIVE TEST item.

4. While operating the test items, check that each interior room lamp turns ON/OFF.

Does the interior room lamp turns ON/OFF (gradual brightening/dimming)?

YES

>> Interior room lamp control circuit is normal.

NO

>> Refer to 

INL-43, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009695423

Regarding Wiring Diagram information, refer to 

INL-21, "Wiring Diagram"

.

1.

CHECK INTERIOR ROOM LAMP CONTROL OUTPUT

CONSULT

1. Turn ignition switch OFF.

2. Remove all the bulbs of map lamp and interior room lamp.

3. Turn ignition switch ON.

4. Select INT LAMP of BCM (INT LAMP) ACTIVE TEST item.

5. While operating the test item, check continuity between BCM harness connector and ground.

With Intelligent Key

Without Intelligent Key

Is the inspection result normal?

YES

>> GO TO 2.

Fixed ON>>GO TO 3.

On

: Interior room lamp gradual brightening

Off

: Interior room lamp gradual dimming

BCM

Ground

Test item

Continuity

Connector

Terminal

M99

63

INT LAMP

On

Yes

Off

No

BCM

Ground

Test item

Continuity

Connector

Terminal

M19

45

INT LAMP

On

Yes

Off

No

 

 

 

 

 

 

 

Content   ..  516  517  518  519   ..