DOOR LOCK ACTUATOR DLK-81 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] C D E F G H I J L M A B DLK N O P 2. CHECK DOOR LOCK ACTUATOR CIRCUIT 1. Disconnect BCM connector and all door lock actuator connectors. 2. Check continuity between BCM harness connector and rear door lock actuator LH harness connector. 3. Check continuity between BCM harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness. 3. CHECK BCM OUTPUT SIGNAL 1. Connect BCM connector. 2. Check voltage between rear door lock actuator LH harness connector and ground. Is the inspection result normal? YES >> Check for internal short of each door lock actuator. NO >> Replace BCM. Refer to BCS-70, "Removal and Installation" REAR RH INFOID:0000000009645312 1. CHECK FUNCTION 1. Select DOOR LOCK of BCM using CONSULT. 2. Select DOOR LOCK in ACTIVE TEST mode. 3. Touch ALL LOCK or ALL UNLK to check that it works normally. YES >> Door lock actuator is OK. NO >> Refer to DLK-81, "REAR RH : Diagnosis Procedure" . REAR RH : Diagnosis Procedure INFOID:0000000009645313 Regarding Wiring Diagram information, refer to DLK-51, "POWER DOOR LOCK SYSTEM : Wiring Diagram" . 1. CHECK DOOR LOCK ACTUATOR INPUT SIGNAL 1. Turn ignition switch OFF. 2. Disconnect rear door lock actuator RH connector. 3. Check voltage between rear door lock actuator RH harness connector and ground. BCM Rear door lock actuator LH Continuity Connector Terminal Connector Terminal M99 65 D205 1 Yes 55 2 BCM Ground Continuity Connector Terminal M99 65 No 55 (+) (–) Condition Voltage (Approx.) BCM Connector Terminal M99 65 Ground Door lock and unlock switch Lock Battery voltage 55 Unlock |