HAC-150 < BASIC INSPECTION > [MANUAL AIR CONDITIONING] OPERATION INSPECTION 4. Press REC ( ) switch one more time. REC indicator should go off. Is the test result normal? YES >> GO TO 7. NO >> Refer to HAC-167, "FRONT A/C CONTROL : Diagnosis Procedure" 7. CHECK INTAKE DOOR OPERATION 1. Press REC ( ) switch one time. REC indicator should illuminate. 2. Listen to the sound of the air coming out of the vent. ) switch one more time. REC indicator should go off. 4. There should be an audible change to the sound of the air flowing out of the vent. YES >> GO TO 8. NO >> Refer to HAC-158, "Diagnosis Procedure" 8. CHECK TEMPERATURE DECREASE 1. Press A/C switch. 2. Rotate temperature control dial counterclockwise until maximum cold. 3. Check for cold air at selected discharge air outlets. YES >> GO TO 9. NO >> Refer to HAC-176, "Component Function Check" 9. CHECK TEMPERATURE INCREASE 1. Rotate temperature control dial clockwise until maximum hot. 2. Check for hot air at appropriate discharge air outlets. YES >> Inspection End. NO >> Refer to |