DIAGNOSIS SYSTEM (BCM)
SEC-25
< FUNCTION DIAGNOSIS >
[INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
SEC
N
O
P
ACTIVE TEST
RKE-P/W OPEN
Indicates [ON/OFF] condition of P/W DOWN signal from Intelligent Key.
RKE-MODE CHG
Indicates [ON/OFF] condition of MODE CHANGE signal from Intelligent Key.
Monitor item
Condition
Test item
Description
BATTERY SAVER
This test is able to check interior room lamp operation.
The interior room lamp will be activated after “ON” on CONSULT-III screen is touched.
PW REMOTO DOWN SET
This test is able to check power window down operation.
The power window down will be activated after “ON” on CONSULT-III screen is touched.
OUTSIDE BUZZER
This test is able to check Intelligent Key warning buzzer operation.
Intelligent Key warning buzzer sounds when “ON” on CONSULT-III screen is touched.
INSIDE BUZZER
This test is able to check warning chime in combination meter operation.
• Take away warning chime sounds when “TAKE OUT” on CONSULT-III screen is touched.
• Key warning chime sounds when “KEY WARN” on CONSULT-III screen is touched.
• P position warning chime sounds when “P RNG WARN” on CONSULT-III screen is touched.
• ACC warning chime sounds when “ACC WARN” on CONSULT-III screen is touched.
INDICATOR
This test is able to check warning lamp operation.
• “KEY” Warning lamp illuminates when “KEY IND ON” on CONSULT-III screen is touched.
• “KEY” Warning lamp flashes when “KEY IND FSH” on CONSULT-III screen is touched.
INT LAMP
This test is able to check interior room lamp operation.
The interior room lamp will be activated after “ON” on CONSULT-III screen is touched.
LCD
This test is able to check meter display information
• Engine start information displays when “BRAKE/P” on CONSULT-III screen is touched.
• Engine start information displays when “BRAKE/P/ON” on CONSULT-III screen is touched.
• Key ID warning displays when “KEY ID NG” on CONSULT-III screen is touched.
• Steering lock information displays when “STLCK RELES” on CONSULT-III screen is touched.
• P position warning displays when “P RNG IND” on CONSULT-III screen is touched.
• Intelligent Key insert information displays when “INSERT KEY” on CONSULT-III screen is
touched.
• Intelligent Key low battery warning displays when “KEY BAT LOW” on CONSULT-III screen is
touched.
• Take away through window warning displays when “TK AWAY WDW” on CONSULT-III screen
is touched.
• Take away warning display when “TAKE AWAY” on CONSULT-III screen is touched.
• OFF position warning display when “IGN OFF WARN” on CONSULT-III screen is touched.
TRUNK/GLASS HATCH
This test is able to check trunk lid opener actuator open operation.
This actuator opens when “ON” on CONSULT-III screen is touched.
FLASHER
This test is able to check security hazard lamp operation.
The hazard lamps will be activated after “ON” on CONSULT-III screen is touched.
HORN
This test is able to check horn operation.
The horn will be activated after “ON” on CONSULT-III screen is touched.
IGN CONT2
This test is able to check security hazard lamp operation.
The hazard lamps will be activated after “ON” on CONSULT-III screen is touched.
P RANGE
This test is able to check CVT device power supply
CVT device power is supplied when “ON” on CONSULT-III screen is touched.
ENGINE SW ILLUMI
This test is able to check push-ignition switch illumination operation.
Push-ignition switch illumination illuminates when “ON” on CONSULT-III screen is touched.
LOCK INDCATOR
This test is able to check LOCK indicator in push-ignition switch operation.
LOCK indicator in push-ignition switch illuminates when “ON” on CONSULT-III screen is touched.
ACC INDICATOR
This test is able to check ACC indicator in push-ignition switch operation.
LOCK indicator in push-ignition switch illuminates when “ON” on CONSULT-III screen is touched.
IGNITION ON IND
This test is able to check INGITION ON indicator in push-ignition switch operation.
LOCK indicator in push-ignition switch illuminates when “ON” on CONSULT-III screen is touched.
KEY SLOT ILLUMI
This test is able to check key slot illumination operation.
Key slot illumination flash when “ON” on CONSULT-III screen is touched.