INSUFFICIENT HEATING HAC-153 < SYMPTOM DIAGNOSIS > [AUTOMATIC AIR CONDITIONER] C D E F G H J K L M A B HAC N O P INSUFFICIENT HEATING Description INFOID:0000000004215396 Symptom • Insufficient heating • No warm air comes out. (Air flow volume is normal.) Inspection procedure INFOID:0000000004215397 1. CHECK DTC Check DTC. YES >> Check according to NO >> GO TO 2. 2. CHECK COOLING SYSTEM 1. Check engine coolant level and check for leakage. Refer to CO-11, "Changing Engine Coolant" . 2. Check radiator cap. Refer to 3. Check water flow sounds of engine coolant. Refer to CO-11, "Changing Engine Coolant" . Is the inspection result normal? YES >> GO TO 3. NO >> Refill the engine coolant and repair or replace the parts according to the inspection results. 3. CHECK SETTING OF TEMPERATURE SETTING TRIMMER Check the setting of temperature setting trimmer using CONSULT-III. Refer to . 1. Perform “TEMP SET CORRECT” in “WORK SUPPORT” with CONSULT-III 2. Check that the temperature setting trimmer is set to “ − direction”. NOTE: The control temperature can be set with the setting of temperature setting trimmer. 3. Set “TEMP SET CORRECT” to “0.0 °C (0.0°F)”. Are the symptoms solved? YES >> Perform the setting separately if necessary. END. NO >> GO TO 4. 4. CHECK OPERATION 1. Turn temperature dial (driver side) and raise temperature setting to 32 °C (90°F) after warming up the engine. 2. Check that warm air blows from outlets. YES >> END. NO >> GO TO 5. 5. CHECK AIR LEAKAGE FROM DUCT Check duct and nozzle, etc. of A/C system for air leakage. YES >> GO TO 6. NO >> Repair or replace parts according to the inspection results. 6. CHECK HEATER PUMP Check heater pump function. Refer to HAC-84, "Component Function Check" Is the inspection result normal? YES >> GO TO 7. NO >> Repair or replace parts according to the inspection results. 7. CHECK HEATER HOSE INSTALLATION CONDITION |