SEC-96 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] B2608 STARTER RELAY Is the inspection result normal? YES >> GO TO 4. NO >> GO TO 3. 3. CHECK STARTER RELAY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect IPDM E/R. 3. Disconnect BCM connector. 4. Check continuity between IPDM E/R harness connector and BCM harness connector. 5. Check continuity between starter relay harness connector and ground. Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace harness. 4. REPLACE BCM 1. Replace BCM. Refer to BCS-73, "Removal and Installation" . 2. Perform initialization of BCM and registration of all Intelligent Keys using CONSULT. 3. Perform DTC CONFIRMATION PROCEDURE for B2605. Refer to . Is DTC B2605 detected again? YES >> Replace IPDM E/R. Refer to PCS-30, "Removal and Installation" NO >> Inspection End. (+) (–) Condition Voltage (V) (Approx.) BCM Connector Terminal M83 74 Ground CVT selector lever N or P position Battery voltage Other than above 0 M/T clutch pedal Depressed Battery voltage Released 0 IPDM E/R BCM Continuity Connector Terminal Connector Terminal E46 44 M83 74 Yes IPDM E/R Ground Continuity Connector Terminal E46 44 No |