BATTERY SAVER OUTPUT/POWER SUPPLY CIRCUIT INL-43 < DTC/CIRCUIT DIAGNOSIS > C D E F G H I J K M A B INL N O P BATTERY SAVER OUTPUT/POWER SUPPLY CIRCUIT Description INFOID:0000000009757586 Provides the battery saver output/power supply. Also cuts the power supply when the interior lamp battery saver is activated. Component Function Check INFOID:0000000009757587 1. CHECK BATTERY SAVER OUTPUT/POWER SUPPLY FUNCTION CONSULT 1. Turn ignition switch ON. 2. Turn each interior lamp to the ON position. - Interior room lamp - Vanity mirror lamps - Map lamp - Trunk room lamp 3. Select BATTERY SAVER of BCM (BATTERY SAVER) active test item. 4. While operating the test item, check that each interior room lamp turns ON/OFF. Is the inspection result normal? YES >> Battery saver output/power supply circuit is normal. NO >> Refer to . Diagnosis Procedure INFOID:0000000009757588 Regarding Wiring Diagram information, refer to . 1. CHECK BATTERY SAVER OUTPUT/POWER SUPPLY OUTPUT CONSULT 1. Turn ignition switch ON. 2. Select BATTERY SAVER of BCM (BATTERY SAVER) active test item. 3. While operating the test item, check voltage between BCM connector and ground. With Intelligent Key Without Intelligent Key Is the inspection result normal? YES >> GO TO 2. NO >> Replace BCM after making sure battery saver output/power supply circuit is not shorted to volt- BCS-73, "Removal and Installation" (with Intelligent Key) or (without Intelligent Key). 2. CHECK BATTERY SAVER OUTPUT/POWER SUPPLY OPEN CIRCUIT OFF : Interior room lamp OFF ON : Interior room lamp ON BCM Ground Test item Voltage Connector Terminal BATTERY SAVER M85 89 OFF 0V ON Battery voltage BCM Ground Test item Voltage Connector Terminal BATTERY SAVER M20 62 OFF 0V ON Battery voltage |