P3097-P30A2 CELL CONTROLLER ASIC OPEN EVB-91 < DTC/CIRCUIT DIAGNOSIS > D E F G H I J K L M A B EVB N O P P3097-P30A2 CELL CONTROLLER ASIC OPEN DTC Logic INFOID:0000000010121079 DTC DETECTION LOGIC DTC DETECTION LOGIC 1. PERFORM DTC CONFIRMATION PROCEDURE With CONSULT 1. Power switch ON and wait for 10 seconds or more. 2. Select “Self Diagnostic Result” of “HV BAT”. 3. Check DTC. YES >> Refer to . NO >> INSPECTION END Diagnosis Procedure INFOID:0000000010121080 DANGER: Since hybrid vehicles and electric vehicles contain a high voltage battery, there is the risk of electric shock, electric leakage, or similar accidents if the high voltage component and vehicle are handled incorrectly. Be sure to follow the correct work procedures when performing inspection and maintenance. WARNING: • Be sure to remove the service plug in order to disconnect the high voltage circuits before perform- ing inspection or maintenance of high voltage system harnesses and parts. • The removed service plug must always be carried in a pocket of the responsible worker or placed in the tool box during the procedure to prevent the plug from being connected by mistake. • Be sure to wear insulating protective equipment consisting of glove, shoes, face shield and glasses before beginning work on the high voltage system. • Never allow workers other than the responsible person to touch the vehicle containing high voltage parts. To keep others from touching the high voltage parts, these parts must be covered with an insu- lating sheet except when using them. • Refer to EVB-7, "High Voltage Precautions" . CAUTION: Never bring the vehicle into the READY status with the service plug removed unless otherwise instructed in the Service Manual. A malfunction may occur if this is not observed. 1. PERFORM THE SELF-DIAGNOSIS OF LI-ION BATTERY CONTROLLER DTC Trouble diagnosis name DTC detecting condition Possible causes P3097 CELL CONT ASIC13 OPEN Self diagnosis program of Li-ion battery controller de- • Li-ion battery controller P3098 CELL CONT ASIC14 OPEN P3099 CELL CONT ASIC15 OPEN P309A CELL CONT ASIC16 OPEN P309B CELL CONT ASIC17 OPEN P309C CELL CONT ASIC18 OPEN P309D CELL CONT ASIC19 OPEN P309E CELL CONT ASIC20 OPEN P309F CELL CONT ASIC21 OPEN P30A0 CELL CONT ASIC22 OPEN P30A1 CELL CONT ASIC23 OPEN P30A2 CELL CONT ASIC24 OPEN |