POWER SUPPLY CIRCUIT FOR ECM EC-1303 [VG33ER] C D E F G H I J K L M A EC 13. CHECK ECM RELAY 1. Apply 12V direct current between relay terminals 1 and 2. 2. Check continuity between relay terminals 3 and 5. OK or NG OK >> GO TO 14. NG >> Replace ECM relay. 14. CHECK ECM GROUND CIRCUIT-II FOR OPEN AND SHORT 1. Turn ignition switch OFF. 2. Disconnect ECM harness connector. 3. Check harness continuity between ECM terminals 10, 19, 25, 32, 116, 124 and engine ground. 4. Also check harness for short to power. OK or NG OK >> GO TO 15. NG >> GO TO 5. 15. CHECK INTERMITTENT INCIDENT Refer to EC-1297, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" >> INSPECTION END. 12V (1 - 2) applied : Continuity exists. No voltage applied : No continuity SEF090M Continuity should exist. |