REFRIGERANT

HA-25

< PERIODIC MAINTENANCE >

C

D

E

F

G

H

J

K

L

M

A

B

HA

N

O

P

Is the inspection result normal?

YES

>> GO TO 15.

NO

>> Repair or replace parts according to the inspection results. 

15.

CHECK RECOVERY/RECYCLING RECHARGING EQUIPMENT

1.

Disconnect recovery/recycling recharging equipment or manifold gauge set (SST: J-39183). 

2.

Discharge the refrigerant from the high-pressure hose and low-pressure hose of the recovery/recycling
recharging equipment. 

3.

Install the service valve caps. 

>> INSPECTION END

HA-26

< PERIODIC MAINTENANCE >

REFRIGERATION SYSTEM

REFRIGERATION SYSTEM

Inspection

INFOID:0000000009160191

1.

CHECK THE BLOWER MOTOR OPERATION

Check the blower motor operation. (This work should be performed by GT-R certified NISSAN dealer.)
Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair or replace the parts according to the inspection results.

2.

CHECK COMPRESSOR OPERATION

Check compressor operation. (This work should be performed by GT-R certified NISSAN dealer.)
Is the inspection result normal?

YES

>> GO TO 3.

NO

>> Repair or replace the parts according to the inspection results.

3.

CHECK REFRIGERANT CYCLE PRESSURE

Connect recovery/recycling recharging equipment to the vehicle and perform the diagnosis with the gauge
pressure. Refer to 

HA-7, "Trouble Diagnosis For Unusual Pressure"

.

Is the inspection result normal?

YES

>> Perform the performance test. Refer to 

HA-26, "Performance Chart"

.

NO

>> Repair or replace the parts according to the inspection results.

Performance Chart

INFOID:0000000009160192

TEST CONDITION

Testing must be performed as per the following:

TEST READING

Recirculating-to-discharge Air Temperature Table

Vehicle condition

Indoors or in the shade (in a well-ventilated place)

Doors

Closed

Door windows

Open

Hood

Open

Temperature control switch or dial

Maximum cold

Mode switch

 (Ventilation) set

Intake switch

 (Recirculation) set

 Fan (blower) speed

Maximum speed set

Engine speed

Idle speed

Operate the air conditioning system for 10 minutes before taking measurements.

Inside air (Recirculating air) at blower assembly inlet

Discharge air temperature at center ventilator

°

C (

°

F)

Relative humidity

%

Air temperature

°

C (

°

F)

50 - 60

20 (68)

6.0 – 8.0 (43 – 46)

25 (77)

8.4 – 10.9 (47 – 52)

30 (86)

14.5 – 17.5 (58 – 64)

60 - 70

20 (68)

7.1 – 9.1 (45 – 48)

25 (77)

10.9 – 13.4 (52 – 57)

30 (86)

17.5 – 20.5 (64 – 69)

REFRIGERATION SYSTEM

HA-27

< PERIODIC MAINTENANCE >

C

D

E

F

G

H

J

K

L

M

A

B

HA

N

O

P

Ambient Air Temperature-to-operating Pressure Table

Refrigerant Leakages

INFOID:0000000009160193

Perform a visual inspection of all refrigeration parts, fittings, hoses and components for signs of A/C lubricant
leakage, damage and corrosion. A/C lubricant leakage may indicate an area of refrigerant leakage. Allow
extra inspection time in these areas when using either an electrical leak detector or fluorescent dye leak
detector [refrigerant dye leak detection kit (SST: J-43926)].
Confirm the leakage with an electrical leak detector if dye is observed. It is possible a prior leakage was
repaired and not properly cleaned.
If a leakage is found but continue checking for additional leakages at all system components and connections
when searching for leakages.
Move the probe along the suspected leakage area at 1 to 2 inches per second and no further than 1/4 inch
from the component when searching for refrigerant leakages using an electrical leak detector.
NOTE:
Moving the electrical leak detector probe slower and closer to the suspected leakage area improves the
chances of finding a leakage.

Ambient air

High-pressure (Discharge side)

kPa (kg/cm

2

, psi)

Low-pressure (Suction side)

kPa (kg/cm

2

, psi)

Relative humidity

%

Air temperature

°

C (

°

F)

50 - 70

25 (77)

1,204 – 1,471

(12.3 – 15.0, 174.6 – 213.3)

171 – 209

(1.7 – 2.1, 24.8 – 30.3)

30 (86)

1,300 – 1,590

(13.3 – 16.2, 188.5 – 230.6)

196 – 240

(2.0 – 2.4, 28.4 – 34.8)

35 (95)

1,500 – 1,820

(15.3 – 18.6, 217.5 – 263.9)

229 – 280

(2.3 – 2.9, 33.2 – 40.6)

40 (104)

1,870 – 2,285

(19.1 – 23.3, 271.2 – 331.3)

292 – 357

(3.0 – 3.6, 42.3 – 51.8)

HA-28

< PERIODIC MAINTENANCE >

FLUORESCENT LEAK DETECTOR

FLUORESCENT LEAK DETECTOR

Inspection

INFOID:0000000009160194

CHECKING SYSTEM FOR LEAKAGES USING THE FLUORESCENT LEAK DETECTOR

1.

Check A/C system for leakages using the UV lamp and safety goggles (SST: J-42220) in a low sunlight
area (area without windows preferable). Illuminate all components, fittings and lines. The dye appears as
a bright green/yellow area at the point of leakage. Fluorescent dye observed at the evaporator drain open-
ing indicates an evaporator core assembly (tubes, core or expansion valve) leakage.

2.

Use an adjustable mirror or wipe the area with a clean shop rag or cloth, with the UV lamp for dye residue
if the suspected area is difficult to see.

3.

Remove any residual dye using dye cleaner (SST: J-43872) to prevent future misdiagnosis after the leak-
age is repaired.

4.

Perform a system performance check and verify the leakage repair with an approved electrical leak detec-
tor.

NOTE:
Other gases in the work area or substances on the A/C components, for example, anti-freeze, windshield
washer fluid, solvents and lubricants, may falsely trigger the leak detector. Make sure the surfaces to be
checked are clean.
Clean with a dry cloth or blow off with shop air.
Do not allow the sensor tip of the detector to contact with any substance. This may also cause false readings
and may damage the detector.

DYE INJECTION

(This procedure is only necessary when recharging the system or when the compressor has seized and was
replaced.)

1.

Check A/C system static (at rest) pressure. Pressure must be at least 345 kPa (3.52 kg/cm

2

, 50 psi).

2.

Pour one bottle [1/4 ounce (7.4 cc)] of the A/C refrigerant dye into the injector tool (SST: J-41459).

3.

Connect the injector tool to the A/C low-pressure side service valve.

4.

Start the engine. Then A/C switch ON.

5.

Inject one bottle [1/4 ounce (7.4 cc)] of fluorescent dye through the low-pressure service valve using dye
injector tool (SST: J-41459) (refer to the manufacture’s operating instructions) when the A/C operating
(compressor running).

6.

Disconnect the injector tool from the service valve with the engine still running.

CAUTION:

Be careful when replacing the A/C system or a component, pour the dye directly into the open sys-
tem connection and proceed with the service procedures.

7.

Operate the A/C system for a minimum of 20 minutes to mix the dye with the system oil. Depending on the
leakage size, operating conditions and location of the leakage, it may take from minutes to days for the
dye to penetrate a leakage and become visible.

8.

Attach a blue label if necessary.

 

 

 

 

 

 

 

содержание   ..  156  157  158  159   ..