EXL-42 < COMPONENT DIAGNOSIS > [XENON TYPE] B2084 VOLTAGE UNDER LIMIT B2084 VOLTAGE UNDER LIMIT DTC Logic INFOID:0000000003805608 DTC DETECTION LOGIC [B2084] VOLTAGE UNDER LIMIT DTC CONFIRMATION PROCEDURE 1. ERASE DTC Erase DTC memory of headlamp levelizer with self-diagnosis of CONSULT-III. >> GO TO 2. 2. DTC CONFIRMATION 1. Turn the ignition switch ON. 2. Perform self-diagnosis of CONSULT-III. Is B2084 detected? YES >> Refer to . NO >> Refer to GI-35, "Intermittent Incident" . Diagnosis Procedure INFOID:0000000003805609 1. CHECK POWER SUPPLY WITH CONSULT-III 1. Turn ignition switch ON. 2. Turn the lighting switch 1ST. 3. Select "INT SEN VOLT" of HEADLAMP LEVELIZER data monitor item. 4. Check the monitor status. Is the measurement value normal? YES >> Replace the auto levelizer control unit. NO >> GO TO 2. 2. CHECK POWER SUPPLY AND GROUND CIRCUIT Check power supply and ground circuit of auto levelizer control unit. Refer to CONTROL UNIT : Diagnosis Procedure" . Is power supply and ground circuit normal? YES >> Replace the auto levelizer control unit. NO >> Repair or replace the malfunctioning part. DTC detection condition DTC erase conditions Possible causes Ignition power supply to auto levelizer control unit is 9 V or less for Ignition switch OFF • Harness or connector Monitor item Standard value (Approx.) INT SEN VOLT Battery voltage |