EC-414 < SERVICE DATA AND SPECIFICATIONS (SDS) [VQ25DE, VQ35DE] SERVICE DATA AND SPECIFICATIONS (SDS) SERVICE DATA AND SPECIFICATIONS (SDS) SERVICE DATA AND SPECIFICATIONS (SDS) Idle Speed INFOID:0000000003856889 Ignition Timing INFOID:0000000003856890 Calculated Load Value INFOID:0000000003856891 Mass Air Flow Sensor INFOID:0000000003856892 *: Engine is warmed up to normal operating temperature and running under no load. Condition Specification No load (in P or N position) 600 ± 50 rpm Condition Specification No load (in P or N position) 12 ± 5 ° BTDC Condition Specification (Using CONSULT-III or GST) At idle 10 – 35 % At 2,500 rpm 10 – 35 % Supply voltage Battery voltage (11 – 14 V) Output voltage at idle (in N position) 0.9 – 1.2 V* Mass air flow (Using CONSULT-III or GST) 2.0 – 6.0 g·m/sec at idle* 7.0 – 20.0 g·m/sec at 2,500 rpm* |