PCS B2615 BLOWER RELAY CIRCUIT PCS-63 < DTC/CIRCUIT DIAGNOSIS > [POWER DISTRIBUTION SYSTEM] C D E F G H I J K L B A O P N 2. Check continuity between fuse block (J/B) harness connector and BCM harness connector. 3. Check continuity between fuse block (J/B) harness connector and ground. Is the inspection result normal? YES >> Replace BCM. Refer to BCS-78, "Removal and Installation" NO >> Repair or replace harness. 4. CHECK BLOWER RELAY GROUND CIRCUIT Check continuity between blower relay harness connector and ground. Is the inspection result normal? YES >> GO TO 5. NO >> Repair blower relay ground circuit. 5. CHECK BLOWER RELAY POWER SUPPLY CIRCUIT-2 1. Install blower relay. 2. Turn ignition switch ON. 3. Check voltage between blower relay harness connector and ground. Is the inspection result normal? YES >> GO TO 7. NO >> GO TO 6. 6. CHECK BLOWER RELAY PCS-63, "Component Inspection" . Is the inspection result normal? YES >> Replace fuse block (J/B). NO >> Replace blower relay. 7. CHECK INTERMITTENT INCIDENT GI-40, "Intermittent Incident" . >> INSPECTION END Component Inspection INFOID:0000000006939110 1. CHECK BLOWER RELAY 1. Turn ignition switch OFF. 2. Remove blower relay. Fuse block (J/B) BCM Continuity Connector Terminal Connector Terminal E103 6F M122 102 Existed Fuse block (J/B) Ground Continuity Connector Terminal E103 6F Not existed Blower relay Ground Continuity Terminal 2 Existed (+) (–) Voltage (V) (Approx.) Blower relay Terminal 5 Ground Battery voltage Revision: 2012 March 2011 Murano CrossCabriolet |