WATER INLET AND THERMOSTAT ASSEMBLY CO-25 < REMOVAL AND INSTALLATION > C D E F G H I J K L M A CO N P O Inspection INFOID:0000000006939280 INSPECTION AFTER REMOVAL 1. Check valve seating condition at ordinary room temperatures. It should seat tightly. 2. Check valve operation. • If the malfunctioning condition, when valve seating at ordinary room temperature, or measured values are out of the standard, INSPECTION AFTER INSTALLATION • Check for leakage of engine coolant using the radiator cap tester adapter (commercial service tool) and the radiator cap tester (commercial service tool). Refer to . • Start and warm up the engine. Visually check that there is no leakage of engine coolant. Thermostat (Standard) : Refer to . SLC949A Revision: 2012 March 2011 Murano CrossCabriolet |