содержание .. 14 15 16 17 ..
ADP-56 < DTC/CIRCUIT DIAGNOSIS > POWER SUPPLY AND GROUND CIRCUIT 2. CHECK GROUND CIRCUIT Check continuity between the automatic drive positioner control unit harness connector and ground. Is the inspection result normal? YES >> Automatic drive positioner control unit power supply and ground circuit are OK. NO >> Repair or replace harness. AUTOMATIC DRIVE POSITIONER CONTROL UNIT : Special Repair Requirement INFOID:0000000009720680 1. PERFORM ADDITIONAL SERVICE Perform additional service when removing battery negative terminal. >> Refer to ADP-8, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL . Automatic drive positioner control unit Ground Continuity Connector Terminal M104 30 Existed |