содержание .. 962 963 964 965 ..
P0001 FUEL PUMP EC-985 < DTC/CIRCUIT DIAGNOSIS > [R9M] C D E F G H I J K L M A EC N P O P0001 FUEL PUMP DTC Description INFOID:0000000010935646 DTC DETECTION LOGIC POSSIBLE CAUSE • Harness or connectors (Fuel flow actuator circuit is open or shorted.) FAIL-SAFE • EGR valve is closed position DTC CONFIRMATION PROCEDURE 1. PRECONDITIONING If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at >> GO TO 2. 2. PERFORM DTC CONFIRMATION PROCEDURE 1. Turn ignition switch ON and wait at least 1 second. 2. Check DTC. Is DTC detected? YES >> Proceed to . NO-1 >> To check malfunction symptom before repair: Refer to GI-44, "Intermittent Incident" NO-2 >> Confirmation after repair: INSPECTION END Diagnosis Procedure INFOID:0000000010935647 1. CHECK FUEL FLOW ACTUATOR POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect fuel flow actuator harness connector. 3. Turn ignition switch ON. 4. Check the voltage between fuel flow actuator harness connector and ground. Is the inspection result normal? YES >> GO TO 2. DTC No. CONSULT screen terms (Trouble diagnosis content) DTC detecting condition P0001 FUEL FLOW REGULATOR CIRCUIT CLOSED • 2.DEF: INLET FLAP BLOCKED OPEN TOO HIGH • ECM detects a short circuit to ground. + - Voltage Fuel flow actuator Connector Terminal F167 1 Ground Battery voltage |