содержание .. 593 594 595 596 ..
REMINDER FUNCTION DOES NOT OPERATE DLK-721 < SYMPTOM DIAGNOSIS > [TYPE 3] C D E F G H I J L M A B DLK N O P REMINDER FUNCTION DOES NOT OPERATE Diagnosis Procedure INFOID:0000000010708408 1. CHECK DTC WITH BCM AND COMBINATION METER Check that DTC is not detected with BCM and combination meter. YES >> GO TO 2. NO-1 >> Refer to NO-2 >> Refer to . (Combination meter) 2. CHECK HAZARD WARNING LAMP Check hazard warning lamp. DLK-697, "Component Function Check" Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace the malfunctioning parts. 3. REPLACE BCM 1. Replace BCM. Refer to BCS-121, "Removal and Installation" . 2. Confirm the operation after replacement. Is the result normal? YES >> INSPECTION END NO >> Check intermittent incident. Refer to GI-44, "Intermittent Incident" . |