Nissan X-Trail 32. Manual - part 2232

 

  Главная      Nissan     Nissan X-Trail 32 - Service Manual

 

поиск по сайту            

 

 

 

 

 

 

 

 

 

содержание   ..  2230  2231  2232  2233   ..

 

 

Nissan X-Trail 32. Manual - part 2232

 

 

DIAGNOSIS SYSTEM (IPDM E/R)

WW-35

< SYSTEM DESCRIPTION >

C

D

E

F

G

H

I

J

K

M

A

B

WW

N

O

P

VEHICLE SPEED (METER)
[km/h]

Displays the status of the A/C ON signal received from A/C auto amp. via CAN com-
munication.

BAT DISCHARGE COUNT
[—]

Monitor the cumulative discharge value of the battery.
NOTE:
When 65,000 or more is counted, replace the battery.

P LAMP CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the parking lamp circuit.
NOTE:
When the number of parking lamp circuit retries count is 20, this item counts 1.

NMB P LAMP CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
parking lamp circuit.
NOTE:
When the number of short circuits in the parking lamp circuit count is 5 and the igni-
tion switch OFF to ON operation is detected, this item counts 1.

NMB P LAMP CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the parking lamp circuit.

DTRL LH CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the daytime running light (left) circuit.
NOTE:
When the number of daytime running light (left) circuit retries count is 20, this item 
counts 1.

NMB DTRL LH CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
daytime running light (left) circuit.
NOTE:
When the number of short circuits in the daytime running light (left) circuit count is 5 
and the ignition switch OFF to ON operation is detected, this item counts 1.

NMB DTRL LH CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the daytime running light (left) circuit.

DTRL RH CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the daytime running light (right) circuit.
NOTE:
When the number of daytime running light (right) circuit retries count is 20, this item 
counts 1.

NMB DTRL RH CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
daytime running light (right) circuit.
NOTE:
When the number of short circuits in the daytime running light (right) circuit count is 
5 and the ignition switch OFF to ON operation is detected, this item counts 1.

NMB DTRL RH CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the daytime running light (right) circuit.

F FOG LH CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the front fog lamp (left) circuit.
NOTE:
When the number of front fog lamp (left) circuit retries count is 20, this item counts 1.

NMB F FOG LH CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
front fog lamp (left) circuit.
NOTE:
When the number of short circuits in the front fog lamp (left) circuit count is 5 and the 
ignition switch OFF to ON operation is detected, this item counts 1.

NMB F FOG LH CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the front fog lamp (left) circuit.

F FOG RH CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the front fog lamp (right) circuit.
NOTE:
When the number of front fog lamp (right) circuit retries count is 20, this item counts 1.

Monitor Item

[Unit]

Description

WW-36

< SYSTEM DESCRIPTION >

DIAGNOSIS SYSTEM (IPDM E/R)

NMB F FOG RH CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
front fog lamp (right) circuit.
NOTE:
When the number of short circuits in the front fog lamp (right) circuit count is 5 and 
the ignition switch OFF to ON operation is detected, this item counts 1.

NMB F FOG RH CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the front fog lamp (right) circuit.

HL (HI) LH CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the headlamp (HI) (left) circuit.
NOTE:
When the number of headlamp (HI) (left) circuit retries count is 20, this item counts 1.

NMB HL (HI) LH CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
headlamp (HI) (left) circuit.
NOTE:
When the number of short circuits in the headlamp (HI) (left) circuit count is 5 and the 
ignition switch OFF to ON operation is detected, this item counts 1.

NMB HL (HI) LH CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the headlamp (HI) (left) circuit.

HL (HI) RH CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the headlamp (HI) (right) circuit.
NOTE:
When the number of headlamp (HI) (right) circuit retries count is 20, this item counts 
1.

NMB HL (HI) RH CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
headlamp (HI) (right) circuit.
NOTE:
When the number of short circuits in the headlamp (HI) (right) circuit count is 5 and 
the ignition switch OFF to ON operation is detected, this item counts 1.

NMB HL (HI) RH CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the headlamp (HI) (right) circuit.

S/L CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the steering lock circuit.
NOTE:
When the number of steering lock circuit retries count is 20, this item counts 1.

NMB S/L CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
steering lock circuit.
NOTE:
When the number of short circuits in the steering lock circuit count is 5 and the ignition 
switch OFF to ON operation is detected, this item counts 1.

NMB S/L CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the steering lock circuit.

HL (LO) LH CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the headlamp (LO) (left) circuit.
NOTE:
When the number of headlamp (LO) (left) circuit retries count is 20, this item counts 1.

NMB HL (LO) LH CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
headlamp (LO) (left) circuit.
NOTE:
When the number of short circuits in the headlamp (LO) (left) circuit count is 5 and 
the ignition switch OFF to ON operation is detected, this item counts 1.

NMB HL (LO) LH CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the headlamp (LO) (left) circuit.

HL (LO) RH CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the headlamp (LO) (right) circuit.
NOTE:
When the number of headlamp (LO) (right) circuit retries count is 20, this item counts 
1.

Monitor Item

[Unit]

Description

DIAGNOSIS SYSTEM (IPDM E/R)

WW-37

< SYSTEM DESCRIPTION >

C

D

E

F

G

H

I

J

K

M

A

B

WW

N

O

P

ACTIVE TEST

NMB HL (LO) RH CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
headlamp (LO) (right) circuit.
NOTE:
When the number of short circuits in the headlamp (LO) (right) circuit count is 5 and 
the ignition switch OFF to ON operation is detected, this item counts 1.

NMB HL (LO) RH CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the headlamp (LO) (right) circuit.

T LAMP LH CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the tail lamp (left) circuit.
NOTE:
When the number of tail lamp (left) circuit retries count is 20, this item counts 1.

NMB T LAMP LH CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
tail lamp (left) circuit.
NOTE:
When the number of short circuits in the tail lamp (left) circuit count is 5 and the igni-
tion switch OFF to ON operation is detected, this item counts 1.

NMB T LAMP LH CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the tail lamp (left) circuit.

T LAMP RH CIRC MALFUNCTN
[0 – 1]

Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper 
limit of the tail lamp (right) circuit.
NOTE:
When the number of tail lamp (right) circuit retries count is 20, this item counts 1.

NMB T LAMP RH CIRC RETRY
[0 – 20]

Monitor the number of times that the smart FET in IPDM E/R permits the retry of the 
tail lamp (right) circuit.
NOTE:
When the number of short circuits in the tail lamp (right) circuit count is 5 and the ig-
nition switch OFF to ON operation is detected, this item counts 1.

NMB T LAMP RH CIRC SHORT
[0 – 5]

Monitor the number of times that the smart FET in IPDM E/R detects the over current 
of the tail lamp (right) circuit.

BATTERY STATUS
[OK/NG]

Monitor the battery status from the battery output.

Monitor Item

[Unit]

Description

Test item

Operation

Description

HORN

Off

OFF

On

Operates horn relay for 20 ms.

HEADLAMP WASHER

Off

OFF

On

Operates headlamp washer relay for 10 ms.

FRONT WIPER

Off

OFF

Low

Operates the front wiper relay.

High

Operates the front wiper relay and front wiper HI/LO relay.

COMPRESSOR

Off

OFF

On

Operates the A/C relay.

COOLING FAN (MONO)

Off

OFF

Lo

Run the cooling fan at low speed.

Hi

Run the cooling fan at high speed.

HEADLAMP (HI)

Off

OFF

On

Operates the headlamp (HI)

HEADLAMP (LO)

Off

OFF

On

Operates the headlamp (LO).

WW-38

< SYSTEM DESCRIPTION >

DIAGNOSIS SYSTEM (IPDM E/R)

WORK SUPPORT

FRONT FOG LAMP

Off

OFF

On

Operates the front fog lamp.

DAYTIME RUNNING LIGHT

Off

OFF

On

Operates the parking lamp (daytime running light operation).

PARKING LAMP

Off

OFF

On

Operates the parking lamp.

TAIL LAMP

Off

OFF

On

Operates the tail lamp.

OPTIC AXIS ACTIVE TEST

Default

Return the optical axis to the default position.
NOTE:
While the headlamp is OFF, it does not return to the default position.

Lower

Adjust the optical axis to the lowermost point.

Test item

Operation

Description

Work item

Description

SENSOR INITIALIZE

Adjusts the height sensor signal output value in the unloaded vehicle condition.

CML B/DCHRG CRNT CLEAR

In this mode, cumulative battery discharge current is cleared.

 

 

 

 

 

 

 

содержание   ..  2230  2231  2232  2233   ..