содержание .. 157 158 159 160 ..
BRC-102 < BASIC INSPECTION > [WITH VDC (ESP)] CALIBRATION OF DECEL G SENSOR CALIBRATION OF DECEL G SENSOR Description INFOID:0000000010723658 CAUTION: Always perform the decel G sensor calibration before driving when the following operation is per- × : Required —: Not required Work Procedure INFOID:0000000010723659 Decel G sensor calibration CAUTION: Always use CONSULT for the decel G sensor calibration. (It cannot be adjusted other than with CON- 1. CHECK THE VEHICLE STATUS 1. Steer the steering wheel to the straight-ahead position. Stop the vehicle on level surface. 2. Stop the engine. 3. Turn the ignition switch OFF. Is the vehicle stopped in the straight-ahead position on level surface? YES >> GO TO 2. NO >> Steer the steering wheel to the straight-ahead position. Stop the vehicle on level surface. 2. PERFORM DECEL G SENSOR CALIBRATION CAUTION: • Never allow passenger or load on the vehicle. With CONSULT 1. Turn the ignition switch ON. CAUTION: Never start engine. 2. Select “ABS”, “WORK SUPPORT”, “DECEL G SENSOR CALIBRATION” in this order. 3. Select “START”. 4. After approx. 10 seconds, select “END”. 5. Turn ignition switch OFF and then turn it ON again. CAUTION: Be sure to perform the operation above. >> GO TO 3. Procedure Decel G sensor calibration Removing/ installing ABS actuator and electric unit (control unit) × Replacing ABS actuator and electric unit (control unit) × Removing/installing steering components — Replacing steering components — Removing/installing suspension components — Replacing suspension components — Removing/installing tire — Replacing tire — Tire rotation — Adjusting wheel alignment. — |