Content .. 2046 2047 2048 2049 ..
WCS-40 < DTC/CIRCUIT DIAGNOSIS > POWER SUPPLY AND GROUND CIRCUIT DTC/CIRCUIT DIAGNOSIS POWER SUPPLY AND GROUND CIRCUIT COMBINATION METER COMBINATION METER : Diagnosis Procedure INFOID:0000000010438777 Regarding Wiring Diagram information, refer to . 1. CHECK FUSES Check that the following fuses are not blown. Is the fuse blown? YES >> Replace the blown fuse after repairing the affected circuit. NO >> GO TO 2. 2. POWER SUPPLY CIRCUIT CHECK 1. Disconnect combination meter connector. 2. Check voltage between combination meter harness connector M52 terminals 45, 46 and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness or connector. 3. GROUND CIRCUIT CHECK 1. Turn ignition switch OFF. 2. Check continuity between combination meter harness connector and ground. Is the inspection result normal? YES >> Inspection End. NO >> Repair or replace harness or connector. BCM (BODY CONTROL SYSTEM) (WITH INTELLIGENT KEY SYSTEM) BCM (BODY CONTROL SYSTEM) (WITH INTELLIGENT KEY SYSTEM) : Diagnosis INFOID:0000000010438778 Unit Power source Fuse No. Combination meter Battery 2 Ignition switch ON or START 3 Terminals Ignition switch position (+) (–) OFF ON START Connector Terminal M52 45 Ground Battery voltage Battery voltage Battery voltage 46 0V Battery voltage Battery voltage Terminals Continuity (+) (–) Connector Terminal M51 1 Ground Yes M52 52 |