EXL-218
< SYSTEM DESCRIPTION >
[HALOGEN HEADLAMP]
DIAGNOSIS SYSTEM (IPDM E/R)
BAT DISCHAGE COUNT
[—]
Monitor the cumulative discharge value of the battery.
NOTE:
When 65,000 or more is counted, replace the battery. (Only with stop/start system
modls)
P LAMP CIRC MALFUNCTN
[0 – 1]
Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper
limit of the parking lamp circuit.
NOTE:
When the number of parking lamp circuit retries count is 20, this item counts 1.
NMB P LAMP CIRC RETRY
[0 – 20]
Monitor the number of times that the smart FET in IPDM E/R permits the retry of the
parking lamp circuit.
NOTE:
When the number of short circuits in the parking lamp circuit count is 5 and the igni-
tion switch OFF to ON operation is detected, this item counts 1.
NMB P LAMP CIRC SHORT
[0 – 5]
Monitor the number of times that the smart FET in IPDM E/R detects the over current
of the parking lamp circuit.
DTRL LH CIRC MALFUNCTN
[0 – 1]
Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper
limit of the daytime running light (left) circuit.
NOTE:
When the number of daytime running light (left) circuit retries count is 20, this item
counts 1.
NMB DTRL LH CIRC RETRY
[0 – 20]
Monitor the number of times that the smart FET in IPDM E/R permits the retry of the
daytime running light (left) circuit.
NOTE:
When the number of short circuits in the daytime running light (left) circuit count is 5
and the ignition switch OFF to ON operation is detected, this item counts 1.
NMB DTRL LH CIRC SHORT
[0 – 5]
Monitor the number of times that the smart FET in IPDM E/R detects the over current
of the daytime running light (left) circuit.
DTRL RH CIRC MALFUNCTN
[0 – 1]
Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper
limit of the daytime running light (right) circuit.
NOTE:
When the number of daytime running light (right) circuit retries count is 20, this item
counts 1.
NMB DTRL RH CIRC RETRY
[0 – 20]
Monitor the number of times that the smart FET in IPDM E/R permits the retry of the
daytime running light (right) circuit.
NOTE:
When the number of short circuits in the daytime running light (right) circuit count is
5 and the ignition switch OFF to ON operation is detected, this item counts 1.
NMB DTRL RH CIRC SHORT
[0 – 5]
Monitor the number of times that the smart FET in IPDM E/R detects the over current
of the daytime running light (right) circuit.
F FOG LH CIRC MALFUNCTN
[0 – 1]
Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper
limit of the front fog lamp (left) circuit.
NOTE:
When the number of front fog lamp (left) circuit retries count is 20, this item counts 1.
NMB F FOG LH CIRC RETRY
[0 – 20]
Monitor the number of times that the smart FET in IPDM E/R permits the retry of the
front fog lamp (left) circuit.
NOTE:
When the number of short circuits in the front fog lamp (left) circuit count is 5 and the
ignition switch OFF to ON operation is detected, this item counts 1.
NMB F FOG LH CIRC SHORT
[0 – 5]
Monitor the number of times that the smart FET in IPDM E/R detects the over current
of the front fog lamp (left) circuit.
F FOG RH CIRC MALFUNCTN
[0 – 1]
Monitor the number of times that the smart FET in IPDM E/R reaches the retry upper
limit of the front fog lamp (right) circuit.
NOTE:
When the number of front fog lamp (right) circuit retries count is 20, this item counts 1.
Monitor Item
[Unit]
Description