Content .. 1402 1403 1404 1405 ..
DOOR LOCK ACTUATOR DLK-885 < DTC/CIRCUIT DIAGNOSIS > [TYPE 6] C D E F G H I J L M A B DLK N O P RHD models 3. Check continuity between BCM harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace harness. 3. CHECK BCM OUTPUT SIGNAL 1. Connect BCM connector. 2. Check voltage between BCM harness connector and ground. Is the inspection result normal? YES >> Check for internal short of each door lock actuator. NO >> Replace BCM. Refer to BCS-135, "Removal and Installation" . PASSENGER SIDE PASSENGER SIDE : Component Function Check INFOID:0000000010672505 1. CHECK FUNCTION 1. Select “DOOR LOCK” of “BCM” using CONSULT. 2. Select “DOOR LOCK” in “ACTIVE TEST” mode. 3. Check that the function operates normally according to the following conditions. Is the inspection result normal? YES >> Door lock actuator is OK. NO >> Refer to DLK-884, "DRIVER SIDE : Diagnosis Procedure" . PASSENGER SIDE : Diagnosis Procedure INFOID:0000000010672506 1. CHECK DOOR LOCK ACTUATOR INPUT SIGNAL 1. Turn ignition switch OFF. 2. Disconnect front door lock assembly (passenger side) connector. 3. Check voltage between front door lock assembly (passenger side) harness connector and ground. BCM Front door lock assembly (driver side) Continuity Connector Terminal Connector Terminal M68 141 D25 3 Existed 148 2 BCM Ground Continuity Connector Terminal M68 141 Not existed 148 (+) (–) Condition Voltage BCM Connector Terminal M68 141 Ground Door lock and unlock switch Lock 9 – 16 V 148 Unlock Monitor item Status DOOR LOCK ALL LOCK Door lock actuators LOCK ALL UNLOCK UNLOCK |