|
|
Content .. 1137 1138 1139 1140 ..
HAC-192 < BASIC INSPECTION > [MANUAL AIR CONDITIONING] DOOR MOTOR STARTING POSITION RESET DOOR MOTOR STARTING POSITION RESET Description INFOID:0000000010432527 • Step motors are used for the mode door motor air mix door motor, and intake door motor. door position recognized by A/C amp. and the actual door position. • The reset signal is transmitted from A/C amp. to the air mix door motor, mode door motor, and intake door motor, which then perform zero position reset. • After any of the following conditions is met, A/C amp. performs motor zero position reset when the ignition switch is next turned ON. - The ignition switch is turned from ON to OFF a total of 360 times. ing. • If A/C amp., air mix door motor, mode door motor, or intake door motor is removed, it is necessary to perform motor zero position reset using CONSULT. Work Procedure INFOID:0000000010432528 1. PERFORM DOOR MOTOR STARTING POSITION RESET With CONSULT 1. Turn ignition switch ON. 2. Select “Door Motor Starting Position Reset” in “WORK SUPPORT” mode of “HVAC” using CONSULT. 3. Touch “Start” and wait 10 seconds. 4. Make sure the “COMPLETED” is displayed on CONSULT screen. >> INSPECTION END |