CHG POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM OPERATION INSPECTION CHG-23 < BASIC INSPECTION > C D E F G H I J K L B A O P N POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM OPER- Inspection Procedure INFOID:0000000012200373 CAUTION: When performing this inspection, always use a charged battery that has completed the battery inspec- tion. (When the charging rate of the battery is low, the response speed of the voltage change will become slow. This can cause an incorrect inspection.) 1. CHECK ECM (CONSULT) Perform ECM self-diagnosis with CONSULT. Refer to (For NISMO RS models) (Except for NISMO RS models). Self-diagnostic results content No malfunction detected>> GO TO 2. Malfunction detected>> Check applicable parts, and repair or replace corresponding parts. 2. CHECK OPERATION OF POWER GENERATION VOLTAGE VARIABLE CONTROL SYSTEM 1. Connect CONSULT and start the engine. 2. Check that the selector lever is in “P” or “N” position (CVT models) or shifter lever is in neutral position (M/ T models) and that all of the electric loads and A/C, etc. are turned OFF. 3. Select “ALTERNATOR DUTY” at “Active Test” of “ENGINE”, and then check the value of “BATTERY VOLT” monitor when DUTY value of “ALTERNATOR DUTY” is set to 40.0 %. 4. Check the value of “BATTERY VOLT” monitor when DUTY value of “ALTERNATOR DUTY” is set to 80.0%. Is the measurement value within the specification? YES >> INSPECTION END NO >> GO TO 3. 3. CHECK IPDM E/R (CONSULT) Perform IPDM E/R self-diagnosis with CONSULT. Refer to PCS-14, "CONSULT Function (IPDM E/R)" . Self-diagnostic results content No malfunction detected>> GO TO 4. Malfunction detected>> Check applicable parts, and repair or replace corresponding parts. 4. CHECK HARNESS BETWEEN ALTERNATOR AND IPDM E/R 1. Turn ignition switch OFF. 2. Disconnect alternator connector and IPDM E/R connector. 3. Check continuity between alternator harness connector and IPDM E/R harness connector. 4. Check continuity between alternator harness connector and ground. “BATTERY VOLT” : 12 - 13.6 V “BATTERY VOLT” : +0.5 V or more against Alternator IPDM E/R Continuity Connector Terminal Connector Terminal F15 5 E13 33 Existed |