SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-149

Step 2. Pulse check

Check the input signals below which are related to 
the keyless entry system.

OK: The MUT-II/III sounds or the voltmeter 
needle fluctuates.

Q: Is the check result normal?

All the signals are received normally. : 

Go to Step 

3.

The key reminder switch signal is not received. : 

Refer to inspection procedure N-9 "The key 
reminder switch signal is not received 

P.54B-334

."

All the door switch signals are not received. : 

Refer to inspection procedure N-11 "All the 
door switch signals are not received <L.H. 
drive vehicles>

P.54B-342

  or <R.H. drive 

vehicles>

P.54B-346

 ."

The driver's door lock actuator switch signal is not 
received. : 

Refer to inspection procedure N-12 

"The driver's door lock actuator signal is not 
received <L.H. drive vehicles>

P.54B-350

  or 

<R.H. drive vehicles>

P.54B-354

 .

The keyless entry transmitter switch signal is not 
received. : 

Refer to inspection procedure N-14 

"Each switch signal of the keyless entry 
transmitter is not received 

P.54B-366

."

Step 3. Retest the system.

Check the keyless entry system works normally.

Q: Is the check result normal?

YES : 

The trouble can be an intermittent 

malfunction (Refer to GROUP 00 

 How to 

Cope with Intermittent Malfunction 

P.00-6

).

NO : 

Replace the ETACS-ECU.

System switch

Check condition

Key reminder switch

When the inserted 
ignition key is pulled out

All of the door switches

A door is opened when 
all the doors are closed

Driver's door lock 
actuator switch

When the driver's key 
cylinder or inside lock 
knob is unlocked or 
locked

Keyless entry transmitter 
switch

When the switch is 
turned from off to on

SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-150

INSPECTION PROCEDURE E-2: Keyless Entry hazard lamp answerback function or the Room Lamp 
Answerback Function does not Work Normally.

CAUTION

Whenever the ECU is replaced, ensure that the 
input and output signal circuits are normal.
COMMENTS ON TROUBLE SYMPTOM
If the hazard warning lamp and the room lamp work 
normally, the ETACS-ECU may be defective.
Alternatively, it is possible that the keyless entry 
hazard lamp answerback function was disabled by 
the adjustment function.

POSSIBLE CAUSES

Defective turn-signal lamp

Malfunction of the room lamp

Malfunction of the ETACS-ECU

Damaged harness wires and connectors

DIAGNOSIS PROCEDURE

Step 1. Check the adjustment function.

Check that the keyless entry hazard lamp 
answerback function has been enabled by using the 
adjustment function.

Q: Is the check result normal?

YES : 

Go to Step 2.

NO : 

Enable the keyless entry hazard lamp 
answerback function by using the 
adjustment function. (Refer to 

P.54B-393

.)

Step 2. Check the operation of the hazard 
warning lamp.

Check that the hazard warning lamps illuminate 
normally.

Q: Is the check result normal?

YES : 

Go to Step 3.

NO : 

Refer to inspection procedure K-2 "The 
hazard warning lamps do not illuminate 

P.54B-240

".

Step 3. Check the operation of the room lamps.

Check that the room lamps illuminate normally.

Q: Is the check result normal?

YES : 

Go to Step 4.

NO : 

Refer to inspection procedure M-2 "The 
front or rear room lamp does not 
illuminate/extinguish 

P.54B-287

."

Step 4. Retest the system.

Check that the keyless entry hazard lamp 
answerback function or the room lamp answerback 
function work normally.

Q: Is the check result normal?

YES : 

The trouble can be an intermittent 

malfunction (Refer to GROUP 00 

 How to 

Cope with Intermittent Malfunction 

P.00-6

).

NO : 

Replace the ETACS-ECU.

SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-151

INSPECTION PROCEDURE E-3: Encrypted Code cannot be Registered.

CAUTION

Whenever the ECU is replaced, ensure that the 
input and output signal circuits are normal.

COMMENTS ON TROUBLE SYMPTOM
If the encrypted code registration mode is not 
entered, the key reminder switch, the hazard warning 
lamp switch or the ETACS-ECU may be defective.
If the registration is not possible although the 
registration mode is entered, the keyless entry 
transmitter or the ETACS-ECU may be defective.

POSSIBLE CAUSES

Malfunction of the keyless entry transmitter

Malfunction of the ETACS-ECU

Damaged harness wires and connectors

DIAGNOSIS PROCEDURE

Step 1. Check the encrypted code registration 
mode.

Check that the encrypted code registration mode is 
entered.

Q: Is the check result normal?

YES : 

Go to Step 3.

NO : 

Go to Step 2.

Encrypted Transmitter Code Register Mode

ETACS-ECU

INPUT SIGNAL

· HAZARD WARNING LAMP SWITCH
· KEYLESS ENTRY TRANSMITTER SWITCH
· KEY REMINDER SWITCH

SYMPTOM PROCEDURES

SMART WIRING SYSTEM (SWS) NOT USING SWS MONITOR

54B-152

Step 2. Pulse check

Check the input signals below which are related to 
the encrypted code of the keyless entry transmitter.

OK: The MUT-II/III sounds or the voltmeter 
needle fluctuates.

Q: Is the check result normal?

All the signals are received normally. : 

Go to Step 

3.

The key reminder switch signal is not received. : 

Refer to inspection procedure N-9 "The key 
reminder switch signal is not received 

P.54B-334

."

The hazard warning lamp switch signal is not 
received. : 

Refer to inspection procedure N-10 

"The hazard warning lamp switch signal is 
not received 

P.54B-338

."

The keyless entry transmitter switch signal is not 
received. : 

Refer to inspection procedure N-14 

"Each switch signal of the keyless entry 
transmitter is not received 

P.54B-366

."

Step 3. Retest the system.

Check that the encrypted code can be registered.

Q: Is the check result normal?

YES : 

The trouble can be an intermittent 

malfunction (Refer to GROUP 00 

 How to 

Cope with Intermittent Malfunction 

P.00-6

).

NO : 

Replace the ETACS-ECU.

INSPECTION PROCEDURE E-4: The Timer Lock Function does not Work after the Doors have been 
Unlocked by the Keyless Entry System.

CAUTION

Whenever the ECU is replaced, ensure that the 
input and output signal circuits are normal.
COMMENT ON TROUBLE SYMPTOM
If the keyless entry timer lock does not work 
normally, the input signal circuit(s) to the keyless 
entry transmitter or the ETACS-ECU may be 
defective.

POSSIBLE CAUSES

Malfunction of the keyless entry transmitter

Malfunction of the ETACS-ECU

Damaged harness wires and connectors

DIAGNOSIS PROCEDURE

Step 1. Check the operation of the keyless entry 
system.

Check that the keyless entry system works normally.

Q: Is the check result normal?

YES : 

Go to Step 2.

NO : 

Refer to inspection procedure E-1 "Keyless 
entry system does not work 

P.54B-148

."

Step 2. Retest the system.

Check that the timer lock works normally.

Q: Is the check result normal?

YES : 

The trouble can be an intermittent 

malfunction (Refer to GROUP 00 

 How to 

Cope with Intermittent Malfunction 

P.00-6

).

NO : 

Replace the ETACS-ECU.

System switch

Check condition

Key reminder switch

When the inserted 
ignition key is pulled out

Hazard warning lamp 
switch

When the switch is 
turned from off to on

Keyless entry transmitter 
switch

When the switch is 
turned from off to on

 

 

 

 

 

 

 

Content   ..  463  464  465  466   ..