 (such as compression

 fitting)  ...............  B  ............  Require replacement.

Flange leaking  ..........  A  ..  Require repair or replacement.

Leaking  .................  A  ..  Require repair or replacement.

Restricted internally  ...  A  ..  Require repair or replacement.

Threads damaged  .........  A  ..  Require repair or replacement.

Threads stripped (threads

 missing)  ...............  A  ............  Require replacement.



         EXPANSION VALVES

EXPANSION VALVE INSPECTION



Condition                 Code                          Procedure

Application incorrect  ...  B  ............  Require replacement.

Attaching hardware

 broken  .................  A  ...  Require repair or replacement

                                                     of hardware.

Attaching hardware

 missing  ................  C  ..........  Require replacement of

                                                        hardware.

Attaching hardware not

 functioning  ............  A  ...  Require repair or replacement

                                                     of hardware.

Corroded internally  .....  1  ............  Suggest replacement.

Filter screen torn  ......  A  ..  Require replacement of screen.

Inoperative  .............  A  ...........  ( 1) Require repair or

                                                     replacement.

Leaking  .................  A  ............  Require replacement.

Restricted  ..............  A  ..  Require repair or replacement.

Threads damaged  .........  A  ..  Require repair or replacement.

Threads stripped (threads

 missing)  ...............  A  ............  Require replacement.

(1) - Expansion valve operation may be affected by capillary

      tube location, corrosion, and insulation tape.

      Inoperative includes intermittent operation.



         FUNCTION SELECTORS

         See CONTROL HEADS (FUNCTION SELECTORS).

         FUSES, FUSIBLE LINKS AND CIRCUIT BREAKERS

FUSE, FUSIBLE LINK AND CIRCUIT BREAKER INSPECTION



Condition                 Code                          Procedure

Application incorrect  ...  B  ............  Require replacement.

Blown  ...................  A  ........  (1) Require replacement.

Corroded, affecting

 performance  ............  A  ..  Require repair or replacement.

Corroded, not affecting

 performance  ............  2  ..  Suggest repair or replacement.

Cracked, affecting

 performance  ............  A  ..  Require repair or replacement.

Cracked, not affecting

 performance  ............  1  ..  Suggest repair or replacement.

Inoperative  .............  A  ...  (2) Require replacement.

Insulation damaged,

 conductors exposed  .....  A  ..  Require repair or replacement.

Insulation damaged,

 conductors not exposed  .  1  ..  Suggest repair or replacement.

Missing  .................  C  ............  Require replacement.

Routed incorrectly  ......  B  .................  Require repair.

Secured incorrectly  .....  B  .................  Require repair.

Terminal broken  .........  A  ..  Require repair or replacement.

Terminal burned, affecting

 performance  ............  A  ...........  ( 1) Require repair or

                                                     replacement.

Terminal burned, not

 affecting performance  ..  2  ..  Suggest repair or replacement.

Terminal corroded,

 affecting performance  ..  A  ..  Require repair or replacement.

Terminal corroded, not

 affecting performance  ..  2  ..  Suggest repair or replacement.

Terminal loose, affecting

 performance  ............  B  ..  Require repair or replacement.

Terminal loose, not

 affecting performance  ..  1  ..  Suggest repair or replacement.

(1) - Determine cause and correct prior to replacement

      of part.

(2) - Inoperative includes intermittent operation.



         FUSIBLE LINKS

         See FUSES, FUSIBLE LINKS AND CIRCUIT BREAKERS.

         GASKETS

GASKET INSPECTION



Condition                 Code                          Procedure

Leaking  .................  A  ...........  ( 1) Require repair or

                                                     replacement.

(1) - Require inspection of mating and sealing surface and

      repair or replace as necessary.



         HEATER CASES

         See PLENUMS.

         HEATER CONTROL VALVES

HEATER CONTROL VALVE INSPECTION



Condition                 Code                          Procedure

Application incorrect  ...  B  ............  Require replacement.

Attaching hardware

 broken  .................  A  ...  Require repair or replacement

                                                     of hardware.

Attaching hardware

 missing  ................  C  ..........  Require replacement of

                                                        hardware.

Attaching hardware not

 functioning  ............  A  ...  Require repair or replacement

                                                     of hardware.

Binding  .................  2  ..  Suggest repair or replacement.

Coolant leak  ............  A  ..  Require repair or replacement.

Disconnected  ............  A  ..  Require repair or replacement.

Malfunctioning  ..........  A  ...........  ( 1) Require repair or

                                                     replacement.

Missing  .................  C  ............  Require replacement.

Restricted  ..............  A  ..  Require repair or replacement.

Seized  ..................  A  ..  Require repair or replacement.

Vacuum leak  .............  A  ..  Require repair or replacement.

(1) - Includes inoperative, intermittent operation, or

      failure to perform all functions.



         HEATER CORES

HEATER CORE INSPECTION



Condition                 Code                          Procedure

Air flow obstruction  ....  A  ..  Require repair or replacement.

Attaching hardware

 broken  .................  A  ...  Require repair or replacement

                                                     of hardware.

Attaching hardware

 missing  ................  C  ..........  Require replacement of

                                                        hardware.

Attaching hardware not

 functioning  ............  A  ..   Require repair or replacement

                                                     of hardware.

Connection leaking  ......  A  ..  Require repair or replacement.

Corroded  ................  1  ..  Suggest repair or replacement.

Disconnected  ............  A  ..  Require repair or replacement.

Fins damaged, affecting

 performance  ............  A  ..  Require repair or replacement.

Fins damaged, not

 affecting performance  ..  ..  ........  No service suggested or

                                                        required.

Internal restrictions,

 affecting performance  ..  A  ..  Require repair or replacement.

Leaking  .................  A  ..  Require repair or replacement.

Missing  .................  C  ............  Require replacement.



         HEATER HOSES

HEATER HOSE INSPECTION



Condition                 Code                          Procedure

Application incorrect  ...  B  ............  Require replacement.

Connected incorrectly  ...  A  .................  Require repair.

Corroded, not reusable  ..  1  ............  Suggest replacement.

Cracked  .................  A  ..  Require repair or replacement.

Hard (brittle)  ..........  1  ..  Suggest repair or replacement.

Inner fabric (webbing)

 damaged  ................  A  ............  Require replacement.

Insufficient clamping

 force, allowing hose to

 leak  ...................  A  ..  Require repair or replacement.

Leaking  .................  A  ..  Require repair or replacement.

Maintenance intervals  ...  3  ............  Suggest replacement.

Melted  ..................  1  ..  Suggest repair or replacement.

Missing  .................  C  ............  Require replacement.

Outer covering damaged  ..  1  ............  Suggest replacement.

Outer covering damaged to

 the extent that the inner

 fabric is visible  ......  A  ............  Require replacement.

Protective sleeves

 damaged  ................  2  .  Suggest replacement of sleeves.

Protective sleeves

 missing  ................  2  .  Suggest replacement of sleeves.

Restricted, affecting

 performance  ............  A  ..  Require repair or replacement.

Restricted, not affecting

 performance  ............  2  ..  Suggest repair or replacement.

Routed incorrectly  ......  2  .................  Suggest repair.

Safety clip missing  .....  C  ............  Require replacement.

Spongy  ..................  1  ..  Suggest repair or replacement.

Stripped  ................  A  ............  Require replacement.

Surface cracks (dry-

 rotted)  ................  1  ..  Suggest repair or replacement.

Swollen  .................  B  ............  Require replacement.

Threads damaged  .........  A  ..  Require repair or replacement.

Threads stripped (threads

 missing)  ...............  A  ............  Require replacement.

Type incorrect  ..........  1  ..  Suggest repair or replacement.



         HIGH PRESSURE RELIEF VALVES (HPRV)

HIGH PRESSURE RELIEF VALVE (HPRV) INSPECTION



Condition                 Code                          Procedure

Inoperative  .............  A  ...........  ( 1) Require repair or

                                                     replacement.

Leaking  .................  A  ..  Require repair or replacement.

Missing  .................  C  ............  Require replacement.

Threads damaged  .........  A  ..  Require repair or replacement.

Threads stripped (threads

 missing)  ...............  A  ............  Require replacement.

(1) - Inoperative includes intermittent operation or out of

      OEM specification.



         IDLERS

         See TENSIONERS.

         IN-LINE FILTERS

IN-LINE FILTER INSPECTION



Condition                 Code                          Procedure

Connection leaking  ......  B  ..  Require repair or replacement.

Leaking  .................  A  ..  Require repair or replacement.

Restricted  ..............  A  ............  Require replacement.

Threads damaged  .........  A  ..  Require repair or replacement.

Threads stripped (threads

 missing)  ...............  A  ............  Require replacement.



 

 

 

 

 

 

 