A/T FAULTY OPERATION PREVENTION MECHANISM DIAGNOSIS TSB Revision AUTOMATIC TRANSAXLE 23A-359 INSPECTION PROCEDURE 3: Selector Lever can be Moved from "P" to "R" Position with Brake Pedal . TECHNICAL DESCRIPTION (COMMENT) . TROUBLESHOOTING HINTS • Malfunction of lock cam • Malfunction of key interlock cable DIAGNOSIS STEP 1. Check the connection of lock cam and Q: Is the connection of lock cam and key interlock cable in good condition? YES : Go to Step 2. NO : Repair the connection of lock cam. When STEP 2. Check the fit of the lock cam. Q: Is the lock cam installed correctly? YES : Go to Step 3. NO : Install the lock cam correctly. Refer to . When the brake pedal is depressed with the ignition key at the STEP 3. Check the lock cam. Q: Is the lock cam in good condition? YES : Go to Step 4. NO : Replace the lock cam. Refer to When the brake pedal is depressed with the STEP 4. Check the fit of the key interlock cable. Q: Is the key interlock cable installed correctly? YES : Go to Step 5. NO : Install the key interlock cable correctly. . When the brake pedal is depressed with the ignition key at the STEP 5. Check the key interlock cable. Q: Is the key interlock cable in good condition? YES : No action to be taken. NO : Replace the key interlock cable. Refer to . When the brake pedal is depressed with the ignition key at the |