AUTOMATIC TRANSMISSION DIAGNOSIS AUTOMATIC TRANSMISSION 23A-136 STEP 4. Measure the low-reverse solenoid valve resistance valve side. (2) Measure the resistance between solenoid valve assembly connector B-108 terminals 6 and 10. Resistance value: 2.7 −3.4 Ω [at 20°C] Q: Is the measured resistance 2.7 −3.4 Ω [at 20°C]? YES : Go to Step 6. STEP 5. Measure the solenoid valve resistance at the valve side. (2) Measure the resistance between low-reverse solenoid valve terminals 1 and 2. Resistance value: 2.7 −3.4 Ω [at 20°C (68°F)] Q: Is the measured resistance 2.7 −3.4 Ω [at 20°C (68°F)? YES : Replace the harness wire between A/T control solenoid valve assembly connector B-108 and the NO : Replace the low-reverse solenoid valve. Refer to GROUP 23B, Valve Body AC306322 CONNECTOR: B-108 B-108 (GR) AC TRANSMISSION 2 7 1 8 3 9 4 6 10 5 AC210673 2 7 1 8 3 9 4 6 10 5 B-108 HARNESS CONNECTOR: AB 2 1 AC201141AZ B-108-5 HARNESS CONNECTOR: CONNECTORS: B-108-5 B-108-5 VALVE BODY 10DB110A |