B1806–PASSENGER DOOR LOCK/UNLOCK SWITCH INPUT CIRCUIT LOW – CLUSTER (CONTINUED) 3. DRIVER DOOR LOCK SWITCH MUX CIRCUIT SHORT TO GROUND Turn the ignition off. Disconnect the Cluster C3 connector. Measure the resistance between ground and the Passenger Door Lock Is the resistance below 10000.0 ohms? Yes >> Repair the Passenger Door Lock Switch Mux circuit for a short to ground. Perform BODY VERIFICATION TEST - VER 1. (Refer to 8 No >> Replace the Instrument Cluster. Perform BODY VERIFICATION TEST - VER 1. (Refer to 8 8N - 16 POWER LOCKS - ELECTRICAL DIAGNOSTICS WK |