Content .. 1697 1698 1699 1700 ..
63–FRONT MODE DOOR DRIVER CIRCUIT SHORTED TO GROUND (MTC) (CONTINUED) 2. CHECK THE FRONT MODE DOOR ACTUATOR CIRCUIT RESISTANCE Measure the resistance between the (C266) Front Mode Door Driver Is the resistance below 30.0 ohms? Yes >> Go To 3 No >> Go To 4 3. CHECK THE (C266) FRONT MODE DOOR DRIVER CIRCUIT FOR A SHORT TO THE (C66) FRONT MODE Disconnect the Front Mode Door Actuator harness connector. Measure the resistance between the (C266) Front Mode Door Driver Is the resistance below 10k ohms? Yes >> Repair the (C266) Front Mode Door Driver circuit for a short to the (C66) Front Mode Door Common Driver cir- Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 No >> Replace the Front Mode Door Actuator in accordance with the Service Information. Perform BODY VERIFICATION TEST – VER 1. (Refer to 8 24 - 144 HVAC - ELECTRICAL DIAGNOSTICS WK |