8D–282
WIRING SYSTEM
DTC 1–1 Motor System Short Circuit
STEP
ACTION
VALUE(S)
YES
NO
1. Turn the starter switch off.
2. Disconnect the actuator connector C–37.
3. Measure resistance between actuator side connector
terminal 1 and 2.
NOTE: If control plate position is fully opened or fully
closed, resistance can not be measured.
Is the resistance within range specified in the value(s)
column?
Measure continuity between harness side connector C–37
terminal 1 and the ground, terminal 2 and the ground, and
terminal 1 and 2.
Are the results same as specified in the value(s) columns?
More than 4.2
Ω
No continuity
Go to
step 2
Replace
the control
unit
Replace
the
actuator
Repair or
replace
the
harness
1
2