6E–278 ENGINE DRIVEABILITY AND EMISSIONS 5. Measure the CO concentration for 1-3 minutes, after idlling the engine to allow the CO concentration to 6. Check the CO concentration. 7. If the value is not within specification, adjust the CO concentration. Adjustment Procedure 1. Warm-up the engine. 2. Turn OFF switches of all electrical equipment. 3. Open the CO adjuster cap. 4. Turn the CO adjuster screw checking the CO concentration . 5. Adjust the CO concentration within specification. Specification: NOTE: Apply the liquid gasket to the CO adjuster screw |