POWER SUPPLY AND GROUND CIRCUIT BRC-113 < DTC/CIRCUIT DIAGNOSIS > [WITH VDC] C D E G H I J K L M A B BRC N O P POWER SUPPLY AND GROUND CIRCUIT Description INFOID:0000000006222641 ABS actuator and electric unit (control unit) power supply Diagnosis Procedure INFOID:0000000006222642 1. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) IGNITION POWER SUPPLY (1) 1. Turn the ignition switch OFF. 2. Disconnect ABS actuator and electric unit (control unit) harness connector. 3. Check voltage between ABS actuator and electric unit (control unit) harness connector and ground. 4. Turn the ignition switch ON CAUTION: Never start engine. 5. Check voltage between ABS actuator and electric unit (control unit) harness connector and ground. Is the inspection result normal? YES >> GO TO 3. NO >> GO TO 2. 2. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) IGNITION POWER SUPPLY CIRCUIT (1) 1. Turn the ignition switch OFF. 2. Check 10A fuse (#57). 3. Disconnect IPDM E/R harness connector. 4. Check continuity between ABS actuator and electric unit (control unit) harness connector and IPDM E/R 5. Check for continuity between ABS actuator and electric unit (control unit) harness connector and the Is the inspection result normal? YES >> Perform trouble diagnosis for ignition power supply. Refer to PG-89, "Wiring Diagram - IGNITION NO >> Repair or replace error-detected parts. 3. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) IGNITION POWER SUPPLY (2) 1. Check voltage between ABS actuator and electric unit (control unit) harness connector and ground. ABS actuator and electric unit (control unit) — Voltage Connector Terminal E36 18 Ground Approx. 0 V ABS actuator and electric unit (control unit) — Voltage Connector Terminal E36 18 Ground 10 − 16 V ABS actuator and electric unit (control unit) IPDM E/R Continuity Connector Terminal Connector Terminal E36 18 E15 59 Existed ABS actuator and electric unit (control unit) — Continuity Connector Terminal E36 18 Ground Not existed |