Content .. 1174 1175 1176 1177 ..
SEC-94 < DTC/CIRCUIT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM] B2608 STARTER RELAY 5. Check continuity between IPDM E/R harness connector and ground. Is the inspection result normal? YES >> Replace IPDM E/R. Refer to PCS-32, "Removal and Installation" NO >> Repair or replace harness. 4. CHECK INTERMITTENT INCIDENT GI-40, "Intermittent Incident" >> INSPECTION END IPDM E/R BCM Continuity Connector Terminal Connector Terminal E13 30 M71 97 Existed IPDM E/R Ground Continuity Connector Terminal E13 30 Not existed |