MWI-46 < COMPONENT DIAGNOSIS > B2202 COMMUNICATION ERROR 2 Is the inspection result normal? YES >> GO TO 4. NO >> Replace unified meter and A/C amp. 4. CHECK COMBINATION METER OUTPUT VOLTAGE 1. Turn ignition switch OFF. 2. Disconnect unified meter and A/C amp. connector. 3. Connect combination meter connector. 4. Turn ignition switch ON. 5. Check voltage between combination meter harness connector terminal and ground. Is the inspection result normal? YES >> INSPECTION END NO >> Replace combination meter. Terminal Voltage (Approx.) (+) (–) Unified meter and A/C amp. Connector Terminal M66 27 Ground 5 V Terminal Voltage (Approx.) (+) (–) Combination meter Connector Terminal M53 3 Ground 5 V |