DIAGNOSIS SYSTEM (BCM) INL-17 < FUNCTION DIAGNOSIS > C D E F G H I J K M A B INL N O P ACTIVE TEST BATTERY SAVER BATTERY SAVER : CONSULT-III Function (BCM - BATTERY SAVER) INFOID:0000000003135145 WORK SUPPORT *: Initial setting DATA MONITOR DOOR SW-DR The switch status input from front door switch (driver side) DOOR SW-AS The switch status input from front door switch (passenger side) DOOR SW-RR The switch status input from rear door switch RH DOOR SW- RL The switch status input from rear door switch LH DOOR SW-BK NOTE: CDL LOCK SW Lock switch status received from central door lock switch by power window switch se- CDL UNLOCK SW Unlock switch status received from central door lock switch by power window switch KEY CYL LK-SW Lock switch status received from key cylinder switch by power window switch serial KEY CYL UN-SW Unlock switch status received from key cylinder switch by power window switch serial TRNK/HAT MNTR The switch status input from trunk room lamp switch RKE-LOCK Lock signal status received from remote keyless entry receiver RKE-UNLOCK Unlock signal status received from remote keyless entry receiver Monitor item [Unit] Description Test item Operation Description INT LAMP On Outputs the interior room lamp control signal to turn map lamp and personal lamp ON Off Stops the interior room lamp control signal to turn map lamp and personal lamp OFF. STEP LAMP TEST On Outputs the step lamp control signal to turn step lamp ON. Off Stops the step lamp control signal to turn step lamp OFF. LUGGAGE LAMP TEST On Outputs the trunk room lamp control signal to turn step lamp ON. Off Stops the trunk room lamp control signal to turn step lamp ON. Service item Setting item Setting BATTERY SAVER SET On* With the exterior lamp battery saver function Off Without the exterior lamp battery saver function ROOM LAMP BAT SAV SET On* With the interior room lamp battery saver function Off Without the interior room lamp battery saver function ROOM LAMP TIMER SET MODE 1* 30 min. Sets the interior room lamp battery saver timer operating MODE 2 60 min. |