|
|
LUBRICANT HA-31 < ON-VEHICLE MAINTENANCE > C D E F G H J K L M A B HA N O P *1: No addition of lubricant is needed if the refrigerant leakage is small. Lubricant Adjusting Procedure for Compressor Replacement INFOID:0000000003545468 1. Check recovery/recycling recharging equipment gauges before connecting recovery/recycling recharging 2. Connect recovery/recycling recharging equipment to vehicle. Confirm refrigerant purity in supply tank if NG. 3. Confirm refrigerant purity in vehicle A/C system using recovery/recycling recharging equipment and refrig- HA-12, "Working with HFC-134a (R-134a)" . 4. Discharge refrigerant into the recovery/recycling recharging equipment. Measure lubricant discharged into 5. Drain the lubricant from the old (removed) compressor into a graduated container and recover the amount 6. Drain the lubricant from the new compressor into a separate. Then clean container. 7. Measure an amount of new lubricant installed equal to amount drained from old compressor. Add this 8. Measure an amount of new lubricant equal to the amount recovered during discharging. Add this lubricant 9. Add another 5 m (0.2 US fl oz., 0.2 Imp fl oz.) of lubricant at this time if the liquid tank also needs to be In case of refrigerant leakage 30 (1.0, 1.1) Large leakage — Small leakage *1 Part replaced Lubricant to be added to system Remarks Amount of lubricant m (US fl oz., Imp fl oz.) |