EXL-256 < COMPONENT DIAGNOSIS > [HALOGEN TYPE] HAZARD SWITCH Does continuity exist? YES >> GO TO 3. NO >> Repair the harnesses or connectors. 3. CHECK HAZARD SWITCH SIGNAL SHORT CIRCUIT Check continuity between the multifunction switch harness connector and the ground. Does continuity exist? YES >> Repair the harnesses or connectors. NO >> GO TO 4. 4. CHECK HAZARD SWITCH GROUND OPEN CIRCUIT Check continuity between the multifunction switch harness connector and the ground. Does continuity exist? YES >> Replace the hazard switch (multifunction switch). NO >> Repair the harnesses or connectors. Multifunction switch BCM Continuity Connector Terminal Connector Terminal M72 16 M122 110 Existed Multifunction switch Ground Continuity Connector Terminal M72 16 Not existed Multifunction switch Ground Continuity Connector Terminal M72 1 Existed |