Fig. 119: Connecting Refrigerant Recovery/Recycling/Charging Station To 2. Evacuate the system (see SYSTEM EVACUATION ). during recovery. Use only SP-10 refrigerant oil. 4. Charge the system with the specified amount of R-134a refrigerant. Do not overcharge the system; the A/C compressor will be damaged. Select the appropriate units of measure for your refrigerant charging station. Refrigerant Capacity: 400 to 450 g 5. Check for refrigerant leaks (see REFRIGERANT LEAK TEST ).
2008 Honda Civic EX 2006-08 HVAC Heating/Air Conditioning - Civic (All Except Hybrid)
|