Dodge Ram. Manual - part 103

 

  Index      Dodge     Dodge Ram - service manual 2004 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  101  102  103  104   ..

 

 

Dodge Ram. Manual - part 103

 

 

TEST

ACTION

APPLICABILITY

4

Turn the ignition off.
Disconnect the Ignition Switch harness connector.
Measure the resistance between ground and the Fused B(+) circuit.
Is the resistance below 10K ohms?

All

Yes

→ Repair the Fused B(+) circuit for a short to ground and replace the

fuse.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the Blower Motor and fuse in accordance with the Service

Information.
Perform BODY VERIFICATION TEST - VER 1.

5

Turn the ignition on.
NOTE: The test light must illuminate brightly. Compare the brightness to
that of a direct connection to the battery.
Using a 12-volt test light connected to ground, back probe the Blower Motor Feed
circuit in the Blower Motor harness connector.
Does the test light illuminate brightly?

All

Yes

→ Go To 6

No

→ Go To 9

6

Turn the ignition off.
Connect a jumper wire between ground and the Blower Motor High Driver circuit in
the Blower Motor harness connector.
Turn the ignition on.
Does the blower motor run at high speed?

All

Yes

→ Go To 7

No

→ Replace the Blower Motor in accordance with the Service Infor-

mation.
Perform BODY VERIFICATION TEST - VER 1.

7

Turn the ignition off.
Disconnect the A/C - Heater Control Module C2 harness connector.
Disconnect the Blower Motor harness connector.
Measure the resistance of the Blower Motor High Driver circuit between the A/C -
Heater Control Module C2 harness connector and the Blower Motor harness
connector.
Is the resistance below 5.0 ohms?

All

Yes

→ Go To 8

No

→ Repair the Blower Motor High Driver circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

8

Turn the ignition off.
Disconnect the A/C - Heater Control Module C2 harness connector.
Measure the resistance between ground and the Ground circuit.
Is the resistance below 5.0 ohms?

All

Yes

→ Replace the A/C - Heater Control Module in accordance with the

Service Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Repair the Ground circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

409

HEATING & A/C

*BLOWER MOTOR INOPERATIVE —

Continued

TEST

ACTION

APPLICABILITY

9

Turn the ignition on.
NOTE: The test light must illuminate brightly. Compare the brightness to
that of a direct connection to the battery.
Using a 12-volt test light connected to ground, back probe the Blower Motor Feed
circuit in the Ignition Switch harness connector.
Does the test light illuminate brightly?

All

Yes

→ Repair the Blower Motor Feed circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 10

10

NOTE: The test light must illuminate brightly. Compare the brightness to
that of a direct connection to the battery.
Using a 12-volt test light connected to ground, back probe the Fused B(+) circuit in
the Ignition Switch harness connector.
Does the test light illuminate brightly?

All

Yes

→ Replace the Ignition Switch in accordance with the Service

Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Repair the Fused B(+) circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

410

HEATING & A/C

*BLOWER MOTOR INOPERATIVE —

Continued

Symptom:

*BLOWER MOTOR SPEEDS INCORRECT

POSSIBLE CAUSES

BLOWER MOTOR DRIVER CIRCUIT(S) SHORTED TO GROUND

A/C - HEATER CONTROL MODULE

BLOWER MOTOR DRIVER CIRCUIT(S) SHORTED TO VOLTAGE

BLOWER MOTOR DRIVER CIRCUITS SHORTED TOGETHER

A/C - HEATER CONTROL MODULE - SPEEDS INCORRECT

BLOWER MOTOR DRIVER CIRCUIT(S) OPEN

BLOWER MOTOR RESISTOR BLOCK - OPEN SPEED

TEST

ACTION

APPLICABILITY

1

Turn the Blower control to the Off position.
Turn the ignition on.
Does the blower run?

All

Yes

→ Go To 2

No

→ Go To 3

2

Turn the ignition off.
Disconnect the A/C - Heater Control Module C2 harness connector.
Disconnect the Blower Motor Resistor Block harness connector.
Measure the resistance between ground and each of the Blower Motor Driver circuits.
Is the resistance below 10K ohms on any of the circuits?

All

Yes

→ Repair all Blower Motor Driver circuits with a resistance below

10K ohms for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the A/C - Heater Control Module in accordance with the

Service Information.
Perform BODY VERIFICATION TEST - VER 1.

3

Turn the ignition off.
Disconnect the A/C - Heater Control Module C2 harness connector.
Turn the ignition on.
NOTE: The test light must illuminate brightly. Compare the brightness to
that of a direct connection to the battery.
Using a 12-volt test light connected to ground, back probe each of the Blower Motor
Driver circuits (cavities 2, 3, 7, and 10) in the A/C - Heater Control Module C2
harness connector.
Does the test light illuminate brightly on each circuit?

All

Yes

→ Go To 4

No

→ Go To 6

411

HEATING & A/C

TEST

ACTION

APPLICABILITY

4

Turn the ignition off.
Disconnect the A/C - Heater Control Module C2 harness connector.
Disconnect the Blower Motor Resistor Block harness connector.
Measure the voltage of each of the Blower Motor Driver circuits (cavities 2, 3, 7, and
10).
Is there any voltage present?

All

Yes

→ Repair all Blower Motor Driver circuits with voltage present for a

short to voltage.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 5

5

Turn the ignition off.
Disconnect the A/C - Heater Control Module C2 harness connector.
Disconnect the Blower Motor Resistor Block harness connector.
Measure the resistance between the Low Blower Motor Driver circuit and the M1,
M2, and Blower Motor High Driver circuit.
Measure the resistance between the M1 Blower Motor Driver circuit and the M2 and
Blower Motor High Driver circuit.
Measure the resistance between the M2 Blower Motor Driver circuit and the Blower
Motor High Driver circuit.
Is the resistance below 10K ohms between any of the circuits?

All

Yes

→ Repair the Blower Motor Driver circuits with a resistance below

10K ohms for a short to each other.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the A/C - Heater Control Module in accordance with the

Service Information.
Perform BODY VERIFICATION TEST - VER 1.

6

Turn the ignition off.
Disconnect the A/C - Heater Control Module C2 harness connector.
Disconnect the Blower Motor Resistor Block harness connector.
Measure the resistance of each Blower Motor Driver circuit between the Blower
Motor Resistor Block harness connector and the A/C - Heater Control Module C2
harness connector.
Is the resistance below 5.0 ohms on each of the circuits?

All

Yes

→ Replace the Blower Motor Resistor Block in accordance with the

Service Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Repair all Blower Motor Driver circuits with a resistance above 5

ohms for an open.
Perform BODY VERIFICATION TEST - VER 1.

412

HEATING & A/C

*BLOWER MOTOR SPEEDS INCORRECT —

Continued

 

 

 

 

 

 

 

Content   ..  101  102  103  104   ..