Dodge Ram. Manual - part 98

 

  Index      Dodge     Dodge Ram - service manual 2004 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  96  97  98  99   ..

 

 

Dodge Ram. Manual - part 98

 

 

TEST

ACTION

APPLICABILITY

1

Turn the ignition on.
With the DRBIII

t, read HVAC DTCs.

Does the DRBIII

t display additional HVAC DTCs?

All

Yes

→ Return to the symptom list and choose the symptom(s).

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 2

2

Turn the ignition on.
With the DRBIII

t, check the PCM for any DTCs.

Are any DTCs present?

All

Yes

→ Refer to the Powertrain Diagnostic Information.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

3

Turn the ignition on.
With the DRB in HVAC, Monitor Display, PCI Bus Msgs, look for the applicable
message and displayed value (

9A/C Hi Side Press: XX,9 9Veh Spd: XX,9 9Eng RPM:

XX,

9 9Coolant Temp: XX,9 9Batt Volts: XX,9 9Batt Temp: XX,9 9VIN Msg Pres: YES9).

Does the DRB display NO RESPONSE after the applicable message?

All

Yes

→ Refer to symptom *No Response From PCM (PCI Bus) in the

Communication category.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Replace the A/C - Heater Control Module in accordance with the

Service Information.
Perform BODY VERIFICATION TEST - VER 1.

389

HEATING & A/C

ENGINE GAUGE RX FAILURE (ACTIVE) —

Continued

Symptom:

EVAPORATOR TEMPERATURE SENSOR CIRCUIT OPEN (ACTIVE)

When Monitored and Set Condition:

EVAPORATOR TEMPERATURE SENSOR CIRCUIT OPEN (ACTIVE)

When Monitored:

With the ignition on.

Set Condition:

This DTC will set if the A/C - Heater Control Module sees voltage above

4.9 volts on the Evaporator Temperature Sensor Signal circuit.

POSSIBLE CAUSES

EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT SHORTED HIGH

EVAPORATOR TEMPERATURE SENSOR

EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT OPEN

SENSOR GROUND CIRCUIT OPEN

A/C - HEATER CONTROL MODULE

TEST

ACTION

APPLICABILITY

1

Turn the ignition off.
Disconnect the A/C - Heater Control Module C1 harness connector.
Turn the ignition on.
Measure the voltage between the Evaporator Temperature Sensor Signal circuit and
ground.
Is there any voltage present?

All

Yes

→ Repair the Evaporator Temperature Sensor Signal circuit for a

short to voltage.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 2

2

Turn the ignition off.
NOTE: Ensure that the A/C - Heater Control Module C1 harness connector is
connected to the A/C - Heater Control Module.
Disconnect the Evaporator Temperature Sensor harness connector.
Connect a jumper wire between the Evaporator Temperature Sensor Signal circuit
and the Sensor Ground circuit at the Evaporator Temperature Sensor harness
connector.
Turn the ignition on.
With the DRBIII

t in Sensor Display, read the Evaporator Temperature Sensor

voltage.
Is the voltage below 0.10 volt?

All

Yes

→ Replace the Evaporator Temperature Sensor in accordance with

the Service Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

390

HEATING & A/C

TEST

ACTION

APPLICABILITY

3

Turn the ignition off.
Disconnect the A/C - Heater Control Module C1 harness connector.
Disconnect the Evaporator Temperature Sensor harness connector.
Measure the resistance of the Evaporator Temperature Sensor Signal circuit between
the A/C - Heater Control Module C1 harness connector and the Evaporator Temper-
ature Sensor harness connector.
Is the resistance below 5.0 ohms?

All

Yes

→ Go To 4

No

→ Repair the Evaporator Temperature Sensor Signal circuit for an

open.
Perform BODY VERIFICATION TEST - VER 1.

4

Turn the ignition off.
Disconnect the A/C - Heater Control Module C1 harness connector.
Disconnect the Evaporator Temperature Sensor harness connector.
Measure the resistance of the Sensor Ground circuit between the A/C - Heater
Control Module C1 harness connector and the Evaporator Temperature Sensor
harness connector.
Is the resistance below 5.0 ohms?

All

Yes

→ Replace the A/C - Heater Control Module in accordance with the

Service Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Repair the Sensor Ground circuit for an open.

Perform BODY VERIFICATION TEST - VER 1.

391

HEATING & A/C

EVAPORATOR TEMPERATURE SENSOR CIRCUIT OPEN (ACTIVE) —

Continued

Symptom:

EVAPORATOR TEMPERATURE SENSOR CIRCUIT SHORTED (AC-
TIVE)

When Monitored and Set Condition:

EVAPORATOR TEMPERATURE SENSOR CIRCUIT SHORTED (ACTIVE)

When Monitored:

With the ignition on.

Set Condition:

This DTC will set if the A/C - Heater Control Module sees voltage below

0.06 volts on the Evaporator Temperature Sensor Signal circuit.

POSSIBLE CAUSES

EVAPORATOR TEMPERATURE SENSOR

EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT SHORTED TO GROUND

EVAPORATOR TEMPERATURE SENSOR SIGNAL CIRCUIT SHORTED TO SENSOR GROUND
CIRCUIT

A/C - HEATER CONTROL MODULE

TEST

ACTION

APPLICABILITY

1

Turn the ignition off.
Disconnect the Evaporator Temperature Sensor harness connector.
Turn the ignition on.
With the DRBIII

t in Sensor Display, read the Evaporator Temperature Sensor

voltage.
Does the DRBIII

t display: 4.9 volts or greater?

All

Yes

→ Replace the Evaporator Temperature Sensor in accordance with

the Service Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 2

2

Turn the ignition off.
Disconnect the A/C - Heater Control Module C1 harness connector.
Disconnect the Evaporator Temperature Sensor harness connector.
Measure the resistance between ground and the Evaporator Temperature Sensor
Signal circuit.
Is the resistance above 10K ohms?

All

Yes

→ Go To 3

No

→ Repair the Evaporator Temperature Sensor Signal circuit for a

short to ground.
Perform BODY VERIFICATION TEST - VER 1.

392

HEATING & A/C

 

 

 

 

 

 

 

Content   ..  96  97  98  99   ..