TEST
ACTION
APPLICABILITY
4
Turn ignition off.
Remove the appropriate inner door trim panel to gain access to the Door Lock Motor
connector.
Disconnect the Door Lock Motor connector.
Disconnect the Remote Keyless Entry module connector.
Measure the resistance of the Door Unlock Relay Output wire to ground.
Is the resistance below 1000.0 ohms?
All
Yes
→ Repair the Door Unlock Relay Output wire for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 5
5
Turn ignition off.
Remove the appropriate inner door trim panel to gain access to the Door Lock Motor
connector.
Disconnect the Door Lock Motor connector.
Disconnect the Remote Keyless Entry module connector.
Measure the resistance between the Door Unlock Relay Output circuit and the Door
Lock Relay Output circuit
Is the resistance below 1000.0 ohms?
All
Yes
→ Repair the Door Unlock Relay Output wire for a short to the Door
Lock Relay Output wire.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Go To 6
6
Turn ignition off.
Remove the appropriate inner door trim panel to gain access to the Door Lock Motor
connector.
Disconnect the Door Lock Motor connector.
Disconnect the Remote Keyless Entry module connector.
Measure the resistance of the Door Lock Relay Output wire to ground.
Is the resistance below 1000.0 ohms?
All
Yes
→ Repair the Door Lock Relay Output wire for a short to ground.
Perform BODY VERIFICATION TEST - VER 1.
No
→ Test Complete.
210
POWER DOOR LOCKS/RKE
*ONE PASSENGER DOOR FAILS TO LOCK & UNLOCK —
Continued