Symptom: BATTERY LOSS When Monitored and Set Condition: BATTERY LOSS When Monitored: With the ignition on. Set Condition: When the Instrument Cluster detects that the ignition has been turned on but detects no Fused B(+) circuit. POSSIBLE CAUSES PDC FUSE #13 DEFECTIVE PDC FUSED B(+) CIRCUIT SHORT TO GROUND FUSE BLOCK #4 FUSE DEFECTIVE FUSE BLOCK FUSED B(+) CIRCUIT SHORT TO GROUND B(+) TO PDC #13 FUSE OPEN B(+) TO FUSE BLOCK #4 FUSE OPEN FUSED B(+) CIRCUIT TO INSTRUMENT CLUSTER OPEN INSTRUMENT CLUSTER TEST ACTION APPLICABILITY 1 Turn the ignition off. All Yes → Repair the PDC #13 Fused B(+) circuit for a short to ground. Perform BODY VERIFICATION TEST - VER 1. No → Go To 2 2 Turn the ignition off. All Yes → Repair the Fuse Block Fused B(+) circuit for a short to ground. Perform BODY VERIFICATION TEST - VER 1. No → Go To 3 142 INSTRUMENT CLUSTER |