Dodge Neon / Neon SRT-4. Manual - part 480

 

  Index      Dodge     Dodge Neon / Neon SRT-4 - service repair manual 2005 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  478  479  480  481   ..

 

 

Dodge Neon / Neon SRT-4. Manual - part 480

 

 

Symptom:

BATTERY LOSS

When Monitored and Set Condition:

BATTERY LOSS

When Monitored:

With the ignition on.

Set Condition:

When the Instrument Cluster detects that the ignition has been turned on

but detects no Fused B(+) circuit.

POSSIBLE CAUSES

PDC FUSE #13 DEFECTIVE

PDC FUSED B(+) CIRCUIT SHORT TO GROUND

FUSE BLOCK #4 FUSE DEFECTIVE

FUSE BLOCK FUSED B(+) CIRCUIT SHORT TO GROUND

B(+) TO PDC #13 FUSE OPEN

B(+) TO FUSE BLOCK #4 FUSE OPEN

FUSED B(+) CIRCUIT TO INSTRUMENT CLUSTER OPEN

INSTRUMENT CLUSTER

TEST

ACTION

APPLICABILITY

1

Turn the ignition off.
Remove and inspect the #13 Fuse in the PDC.
If the fuse is open, replace with the proper rated fuse.
Turn the ignition on for approximately 1 minute.
Turn the ignition off.
Remove and inspect the #13 Fuse in the PDC.
Is the #13 Fuse in the PDC open?

All

Yes

→ Repair the PDC #13 Fused B(+) circuit for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 2

2

Turn the ignition off.
Remove and inspect the Fuse Block #4 Fuse.
If the fuse is open, replace with the proper rated fuse.
Turn the ignition on for approximately 1 minute.
Turn the ignition off.
Remove and inspect the Fuse Block #4 Fuse.
Is the Fuse Block #4 Fuse open?

All

Yes

→ Repair the Fuse Block Fused B(+) circuit for a short to ground.

Perform BODY VERIFICATION TEST - VER 1.

No

→ Go To 3

142

INSTRUMENT CLUSTER

TEST

ACTION

APPLICABILITY

3

Turn the ignition off.
Measure the voltage between the PDC #13 Fuse and ground.
Is the voltage above 10.5 volts?

All

Yes

→ Go To 4

No

→ Repair the B(+) circuit to the PDC #13 Fuse for an open.

Perform BODY VERIFICATION TEST - VER 1.

4

Turn the ignition off.
Measure the voltage between the Fuse Block #4 Fuse and ground.
Is the voltage above 10.5 volts?

All

Yes

→ Go To 5

No

→ Repair the B(+) circuit to the Fuse Block #4 Fuse for an open.

Perform BODY VERIFICATION TEST - VER 1.

5

Turn the ignition off.
Disconnect the Instrument Cluster harness connector.
Check connectors - Clean/repair as necessary.
Measure the voltage between the Fused B(+) circuit and ground.
Is the voltage above 10.5 volts?

All

Yes

→ Replace the Instrument Cluster in accordance with the Service

Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Repair the Fused B(+) circuit for an open between the Fuse Block

#4 Fuse and the Instrument Cluster.
Perform BODY VERIFICATION TEST - VER 1.

143

INSTRUMENT CLUSTER

BATTERY LOSS —

Continued

Symptom List:

CLUSTER BUS TX SHUTDOWN
NO PCI BUS TRANSMISSION

Test Note:

All symptoms listed above are diagnosed using the same tests.

The title for the tests will be CLUSTER BUS TX SHUTDOWN.

When Monitored and Set Condition:

CLUSTER BUS TX SHUTDOWN

When Monitored:

Continuous.

Set Condition:

The Instrument Cluster fails the loop- back test on the PCI Bus.

NO PCI BUS TRANSMISSION

When Monitored:

Continous.

Set Condition:

The Instrument Cluster microprocessor fails the loop- back test on the PCI

Bus.

POSSIBLE CAUSES

INSTRUMENT CLUSTER

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, erase DTCs.

Cycle the ignition and wait approximately 1 minute.
With the DRBIII

t, read DTCs.

Did this DTC reset?

All

Yes

→ Replace the Instrument Cluster in accordance with the Service

Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ Test Complete.

144

INSTRUMENT CLUSTER

Symptom:

EATX MISMATCH

When Monitored and Set Condition:

EATX MISMATCH

When Monitored:

With the ignition on.

Set Condition:

The Instrument Cluster detects that the configuration programmed by the

plant does not equal the configuration of the cluster.

POSSIBLE CAUSES

EATX BUS MESSAGE DTC PRESENT

INSTRUMENT CLUSTER CONFIGURATION INCORRECT

INSTRUMENT CLUSTER

TEST

ACTION

APPLICABILITY

1

With the DRBIII

t, read DTCs.

Does the DRBIII

t display 9EATX Bus Message Not Received9?

All

Yes

→ Refer to Communication for the related symptom.

No

→ Go To 2

2

With the DRBIII

t in Cluster Type, ensure that the Instrument Cluster is correctly

configured.
Is the Instrument Cluster configured correctly?

All

Yes

→ Replace the Instrument Cluster in accordance with the Service

Information.
Perform BODY VERIFICATION TEST - VER 1.

No

→ With the DRBIIIt, configure the Instrument Cluster.

Perform BODY VERIFICATION TEST - VER 1.

145

INSTRUMENT CLUSTER

 

 

 

 

 

 

 

Content   ..  478  479  480  481   ..