Symptom: LOW VOLTAGE LEVEL When Monitored and Set Condition: LOW VOLTAGE LEVEL When Monitored: Set Condition: The radio detects lower than normal voltage. POSSIBLE CAUSES CHECK CHARGING SYSTEM CHECK VOLTAGE LEVEL AT RADIO RADIO TEST ACTION APPLICABILITY 1 Check the charging system in accordance with the service information. All Yes → Go To 2 No → Refer to the appropriate service information and repair as neces- sary. 2 Turn the ignition off. All Yes → Go To 3 No → Repair the circuit for high resistance. Perform BODY VERIFICATION TEST - VER 1. 3 Note: Reconnect all previously disconnected components. t, erase the audio DTC’s. Start the engine. t, read the audio DTC’s. Did this DTC reset? All Yes → Replace the Radio. Perform BODY VERIFICATION TEST - VER 1. No → Test Complete. 94 AUDIO |