DAF CF65, CF75, CF85 Series . Manual - part 36

 

  Index      DAF     DAF CF65, CF75, CF85 Series - service repair manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  34  35  36  37   ..

 

 

DAF CF65, CF75, CF85 Series . Manual - part 36

 

 

©

1-1

CDS-3 fault codes

CDS-3

DAVIE XD diagnostics manual 

7

1. CDS-3 FAULT CODES

1.1 INTRODUCTION

If the electronic unit detects a system fault, this 

fault is usually stored in the memory of the 

electronic unit as a fault code.

Most system faults will also generate a warning.

CDS-3

1-2

©

CDS-3 fault codes

7

DAVIE XD diagnostics manual

1.2 EXPLANATORY NOTES TO CDS-3 FAULT CODES

Fault code

Fault code description with possible cause

Symptom

2-4

-

Interruption of motor for central door lock on 
co-driver's side (B200) on pin 12 of the ECU

-

Driver's door cannot be locked/unlocked 
using the remote control

-

Co-driver's door cannot be locked using the 
remote control

-

Co-driver's door cannot be locked using the 
dashboard switch

-

Co-driver's door is not locked if the driver's 
door is key-locked

-

Co-driver's door cannot be unlocked using 
the dashboard switch

-

Driver's door is not locked if the co-driver's 
door is key-locked

-

Interruption of motor for central door lock on 
co-driver's side (B200) on pin 14 of the ECU

-

Driver's door cannot be unlocked using the 
remote control

-

Interruption of motor for central door lock on 
driver's side (B199) on pin 15 of the ECU

-

Driver's door cannot be locked using the 
remote control

-

Co-driver's door cannot be locked using the 
remote control when driver’s door is locked

-

Co-driver's door is not locked if the driver's 
door is key-locked

-

Driver's door is not locked if the co-driver's 
door is key-locked

3-6

Short circuit to earth on pin 2 of the ECU

-

Alarm system is not switched on when 
operating the remote control

-

Alarm system is not switched off when 
operating the remote control

-

Interior lighting does not respond to CDS-3 
signal

©

2-1

System inspection with DAVIE XD

CDS-3

DAVIE XD diagnostics manual 

7

2. SYSTEM INSPECTION WITH DAVIE XD

2.1 GENERAL

When replacing a CDS-3 electronic unit, the unit 

must be initialised by means of DAVIE XD after 

installation. Initialisation includes adjustment of 

the two remote controls.

CDS-3

2-2

©

System inspection with DAVIE XD

7

DAVIE XD diagnostics manual

2.2 MENU "INITIALISING NEW UNIT"

The option "Initialising new unit" can be found in 

the menu "Programming".

This menu consists of three components:

-

activating remote controls

-

deactiving remote controls

-

Initialising new unit

Activating hand-held transmitters
2 remote controls come standard with each CDS-

3 unit. Another 6 remote controls may be added.

Deactivating hand-held transmitters
With this option it is possible to deactivate remote 

controls, for instance when one of the remote 

controls has been lost. With this option all remote 

controls are deactivated, so that at least two 

remote controls will need to be adjusted once 

again.

Initialising new unit
Only a new "empty" unit can be initialised. Once 

initialised, a unit cannot be initialised again with 

this DAVIE XD option.

Having installed the unit, go to menu 

"Programming" in DAVIE XD and select option 

"Initialising new unit".

It is necessary to adjust at least two remote 

controls. The remote control has been adjusted 

when it recognises the signal sent by the remote 

control.

The unit must have recognised this signal four 

times and this needs to be true for both remote 

controls.

Should something go wrong during initialisation 

and should the procedure be aborted because of 

this, the procedure can be repeated after 

renewed startup. A unit, once initialised, cannot 

be initialised again.

 

 

 

 

 

 

 